基于可变分数延迟滤波器的太阳能-光伏-电池系统同步控制

Pavitra Shukl, Bhim Singh
{"title":"基于可变分数延迟滤波器的太阳能-光伏-电池系统同步控制","authors":"Pavitra Shukl, Bhim Singh","doi":"10.1109/ICEPE50861.2021.9404522","DOIUrl":null,"url":null,"abstract":"For solar-photovoltaic (PV)-battery system, a synchronization control based on variable fractional delay filter is analysed here along-with the presence of a battery for ensuring reliable power to critical loads. In compliance with the IEEE-519 standard, the grid currents are obtained without harmonics thereby guaranteeing satisfactory performance along-with reduction in losses of the distribution network. Moreover, during the grid outage or islanded mode of operation, a voltage controller is utilized for power transfer between the PV array, battery and loads. The performance is validated though the simulation results and the system behaviour is observed for weak grid conditions along with grid outage conditions.","PeriodicalId":250203,"journal":{"name":"2020 3rd International Conference on Energy, Power and Environment: Towards Clean Energy Technologies","volume":"130 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Synchronization Control Based on Variable Fractional Delay Filter for Solar-PV-Battery System\",\"authors\":\"Pavitra Shukl, Bhim Singh\",\"doi\":\"10.1109/ICEPE50861.2021.9404522\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"For solar-photovoltaic (PV)-battery system, a synchronization control based on variable fractional delay filter is analysed here along-with the presence of a battery for ensuring reliable power to critical loads. In compliance with the IEEE-519 standard, the grid currents are obtained without harmonics thereby guaranteeing satisfactory performance along-with reduction in losses of the distribution network. Moreover, during the grid outage or islanded mode of operation, a voltage controller is utilized for power transfer between the PV array, battery and loads. The performance is validated though the simulation results and the system behaviour is observed for weak grid conditions along with grid outage conditions.\",\"PeriodicalId\":250203,\"journal\":{\"name\":\"2020 3rd International Conference on Energy, Power and Environment: Towards Clean Energy Technologies\",\"volume\":\"130 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-03-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 3rd International Conference on Energy, Power and Environment: Towards Clean Energy Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEPE50861.2021.9404522\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 3rd International Conference on Energy, Power and Environment: Towards Clean Energy Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEPE50861.2021.9404522","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

针对太阳能光伏(PV)电池系统,分析了基于可变分数阶延迟滤波器的同步控制,并考虑了电池的存在,以确保对关键负载的可靠供电。符合IEEE-519标准,获得的电网电流没有谐波,从而保证了令人满意的性能,同时减少了配电网的损耗。此外,在电网中断或孤岛运行模式下,电压控制器用于光伏阵列、电池和负载之间的电力传输。通过仿真结果验证了系统的性能,并观察了弱电网条件下以及电网中断条件下的系统行为。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Synchronization Control Based on Variable Fractional Delay Filter for Solar-PV-Battery System
For solar-photovoltaic (PV)-battery system, a synchronization control based on variable fractional delay filter is analysed here along-with the presence of a battery for ensuring reliable power to critical loads. In compliance with the IEEE-519 standard, the grid currents are obtained without harmonics thereby guaranteeing satisfactory performance along-with reduction in losses of the distribution network. Moreover, during the grid outage or islanded mode of operation, a voltage controller is utilized for power transfer between the PV array, battery and loads. The performance is validated though the simulation results and the system behaviour is observed for weak grid conditions along with grid outage conditions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信