Yongde Zhang, T. Podder, W. Ng, J. Sherman, V. Misic, D. Fuller, E. Messing, D. Rubens, J. Strang, R. Brasacchio, Yan Yu
{"title":"用于前列腺近距离治疗的半自动针刺和种子输送装置","authors":"Yongde Zhang, T. Podder, W. Ng, J. Sherman, V. Misic, D. Fuller, E. Messing, D. Rubens, J. Strang, R. Brasacchio, Yan Yu","doi":"10.1109/IROS.2006.281890","DOIUrl":null,"url":null,"abstract":"In this paper we present a semi-automated device designed and developed to deliver radio-active seeds for treating prostate cancer. In the brachytherapy procedure a slander needle is inserted through the perineum and passed through different types of tissues. Thus, the needle experiences significant amount of force which may cause it to buckle and bend. In our design, we have considered the buckling force and insertion force on needle by collecting in-vivo data from real patient and performing in-vitro experiments. Techniques to reduce force and organ/tissue deformation have been implemented into this new design. To track the axial force on the needle for detecting pubic arch interference and to improve robotic control, we have incorporated three force sensors. Rigidity and factor of safety of the device has been analyzed using finite element method which was very useful for iterative design process","PeriodicalId":237562,"journal":{"name":"2006 IEEE/RSJ International Conference on Intelligent Robots and Systems","volume":"70 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":"{\"title\":\"Semi-automated Needling and Seed Delivery Device for Prostate Brachytherapy\",\"authors\":\"Yongde Zhang, T. Podder, W. Ng, J. Sherman, V. Misic, D. Fuller, E. Messing, D. Rubens, J. Strang, R. Brasacchio, Yan Yu\",\"doi\":\"10.1109/IROS.2006.281890\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper we present a semi-automated device designed and developed to deliver radio-active seeds for treating prostate cancer. In the brachytherapy procedure a slander needle is inserted through the perineum and passed through different types of tissues. Thus, the needle experiences significant amount of force which may cause it to buckle and bend. In our design, we have considered the buckling force and insertion force on needle by collecting in-vivo data from real patient and performing in-vitro experiments. Techniques to reduce force and organ/tissue deformation have been implemented into this new design. To track the axial force on the needle for detecting pubic arch interference and to improve robotic control, we have incorporated three force sensors. Rigidity and factor of safety of the device has been analyzed using finite element method which was very useful for iterative design process\",\"PeriodicalId\":237562,\"journal\":{\"name\":\"2006 IEEE/RSJ International Conference on Intelligent Robots and Systems\",\"volume\":\"70 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"14\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 IEEE/RSJ International Conference on Intelligent Robots and Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IROS.2006.281890\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE/RSJ International Conference on Intelligent Robots and Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IROS.2006.281890","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Semi-automated Needling and Seed Delivery Device for Prostate Brachytherapy
In this paper we present a semi-automated device designed and developed to deliver radio-active seeds for treating prostate cancer. In the brachytherapy procedure a slander needle is inserted through the perineum and passed through different types of tissues. Thus, the needle experiences significant amount of force which may cause it to buckle and bend. In our design, we have considered the buckling force and insertion force on needle by collecting in-vivo data from real patient and performing in-vitro experiments. Techniques to reduce force and organ/tissue deformation have been implemented into this new design. To track the axial force on the needle for detecting pubic arch interference and to improve robotic control, we have incorporated three force sensors. Rigidity and factor of safety of the device has been analyzed using finite element method which was very useful for iterative design process