{"title":"中压系统用固态断路器和限流装置","authors":"S. Schroder, C. Meyer, R. D. De Doncker","doi":"10.1109/CIEP.2002.1216642","DOIUrl":null,"url":null,"abstract":"State-of-the-art mechanical circuit breakers in medium-voltage systems only allow handling of short-circuits if the short circuit power of the grid is limited. Using delayed turn-off times, the circuit breaker can be coordinated with lower level protection gear. Hence, a high availability of the grid can be guaranteed. However, during a short-circuit a significant voltage sag can be noticed locally in the medium voltage grid. Sensitive loads such as computers will fail even when voltage returns within a few seconds. The proposed semiconductor circuit breaker is able to switch fast enough to keep voltage disturbance within acceptable limits. The realization of the switch with state-of-the-art semiconductors and its impact on the grid is analyzed in this paper.","PeriodicalId":191010,"journal":{"name":"VIII IEEE International Power Electronics Congress, 2002. Technical Proceedings. CIEP 2002.","volume":"94 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"21","resultStr":"{\"title\":\"Solid-state circuit breakers and current-limiting devices for medium-voltage systems\",\"authors\":\"S. Schroder, C. Meyer, R. D. De Doncker\",\"doi\":\"10.1109/CIEP.2002.1216642\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"State-of-the-art mechanical circuit breakers in medium-voltage systems only allow handling of short-circuits if the short circuit power of the grid is limited. Using delayed turn-off times, the circuit breaker can be coordinated with lower level protection gear. Hence, a high availability of the grid can be guaranteed. However, during a short-circuit a significant voltage sag can be noticed locally in the medium voltage grid. Sensitive loads such as computers will fail even when voltage returns within a few seconds. The proposed semiconductor circuit breaker is able to switch fast enough to keep voltage disturbance within acceptable limits. The realization of the switch with state-of-the-art semiconductors and its impact on the grid is analyzed in this paper.\",\"PeriodicalId\":191010,\"journal\":{\"name\":\"VIII IEEE International Power Electronics Congress, 2002. Technical Proceedings. CIEP 2002.\",\"volume\":\"94 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-10-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"21\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"VIII IEEE International Power Electronics Congress, 2002. Technical Proceedings. CIEP 2002.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIEP.2002.1216642\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"VIII IEEE International Power Electronics Congress, 2002. Technical Proceedings. CIEP 2002.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIEP.2002.1216642","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Solid-state circuit breakers and current-limiting devices for medium-voltage systems
State-of-the-art mechanical circuit breakers in medium-voltage systems only allow handling of short-circuits if the short circuit power of the grid is limited. Using delayed turn-off times, the circuit breaker can be coordinated with lower level protection gear. Hence, a high availability of the grid can be guaranteed. However, during a short-circuit a significant voltage sag can be noticed locally in the medium voltage grid. Sensitive loads such as computers will fail even when voltage returns within a few seconds. The proposed semiconductor circuit breaker is able to switch fast enough to keep voltage disturbance within acceptable limits. The realization of the switch with state-of-the-art semiconductors and its impact on the grid is analyzed in this paper.