验证放射治疗的GATE蒙特卡罗代码:Varian Clinac2300C/D

Zakaria Aitelcadi, Y. Toufique, A. El kharrim, S. Elmadani, A. Hilali, O. Bouhali
{"title":"验证放射治疗的GATE蒙特卡罗代码:Varian Clinac2300C/D","authors":"Zakaria Aitelcadi, Y. Toufique, A. El kharrim, S. Elmadani, A. Hilali, O. Bouhali","doi":"10.1109/ICOA.2018.8370602","DOIUrl":null,"url":null,"abstract":"Our work aimed to validate a GATE Modeled of a linear accelerator Clinac2300C/D using GATE 8.0 for 6MV photon beam. The reference measurements were determined by ionization chambers (PTW 31014) and were compared with GATE results. To reduce the computing time, the simulation tasks were splitted into several jobs to run simultaneously in our local cluster. The simulation parameters of GATE were adjusted to validate the accelerator modeling from percentage depth dose and profiles in the reference conditions. Good agreement between simulations and measurements in water was observed. A gamma index comparison was performed, and more than 97% of the points for all simulations passed the 2%/2 mm gamma criterion.","PeriodicalId":433166,"journal":{"name":"2018 4th International Conference on Optimization and Applications (ICOA)","volume":"92 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Validation of the GATE Monte Carlo code for radiation therapy: Varian Clinac2300C/D\",\"authors\":\"Zakaria Aitelcadi, Y. Toufique, A. El kharrim, S. Elmadani, A. Hilali, O. Bouhali\",\"doi\":\"10.1109/ICOA.2018.8370602\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Our work aimed to validate a GATE Modeled of a linear accelerator Clinac2300C/D using GATE 8.0 for 6MV photon beam. The reference measurements were determined by ionization chambers (PTW 31014) and were compared with GATE results. To reduce the computing time, the simulation tasks were splitted into several jobs to run simultaneously in our local cluster. The simulation parameters of GATE were adjusted to validate the accelerator modeling from percentage depth dose and profiles in the reference conditions. Good agreement between simulations and measurements in water was observed. A gamma index comparison was performed, and more than 97% of the points for all simulations passed the 2%/2 mm gamma criterion.\",\"PeriodicalId\":433166,\"journal\":{\"name\":\"2018 4th International Conference on Optimization and Applications (ICOA)\",\"volume\":\"92 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 4th International Conference on Optimization and Applications (ICOA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICOA.2018.8370602\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 4th International Conference on Optimization and Applications (ICOA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICOA.2018.8370602","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文旨在利用GATE 8.0验证直线加速器Clinac2300C/D对6MV光子束的GATE模型。参考测量值由电离室(PTW 31014)测定,并与GATE结果进行比较。为了减少计算时间,我们将模拟任务拆分为多个作业,在本地集群中同时运行。调整了GATE的仿真参数,验证了参考条件下基于百分比深度剂量和剖面的加速器模型。在水中观察到模拟结果与测量结果吻合良好。进行了伽马指数比较,所有模拟的97%以上的点都通过了2%/ 2mm的伽马标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Validation of the GATE Monte Carlo code for radiation therapy: Varian Clinac2300C/D
Our work aimed to validate a GATE Modeled of a linear accelerator Clinac2300C/D using GATE 8.0 for 6MV photon beam. The reference measurements were determined by ionization chambers (PTW 31014) and were compared with GATE results. To reduce the computing time, the simulation tasks were splitted into several jobs to run simultaneously in our local cluster. The simulation parameters of GATE were adjusted to validate the accelerator modeling from percentage depth dose and profiles in the reference conditions. Good agreement between simulations and measurements in water was observed. A gamma index comparison was performed, and more than 97% of the points for all simulations passed the 2%/2 mm gamma criterion.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信