REBCO线圈持续电流运行的高温超导接头性能试验

Kohki Takahashi, S. Awaji
{"title":"REBCO线圈持续电流运行的高温超导接头性能试验","authors":"Kohki Takahashi, S. Awaji","doi":"10.2221/jcsj.55.268","DOIUrl":null,"url":null,"abstract":"Synopsis: The superconducting joint is a key technology to achieve persistent current operation for MRI and NMR magnets, thereby enabling to obtain higher resolution and sensitivity. A persistent current system including a superconducting joint, a persistent current switch and a double pancake coil fabricated with a REBCO tape was prepared by Furukawa Electric Co., Ltd. The magnetic-field decay behaviors during persistent current operation were observed in external fields of 0 and 1 T at 20 K. In a self-field, the decay rate of the persistent current excited up to 170 A reached 1.2 ppm/h after operating for five days, corresponding to a resistance of 5.1  10-13 . From the current–voltage characteristics obtained from the magnetic field decay, it was found that the decay behavior of the persistent current is dominated by joint resistance in the case of high-load operation, but dominated by the shielding current in the case of low-load region of the operating current.","PeriodicalId":143949,"journal":{"name":"TEION KOGAKU (Journal of Cryogenics and Superconductivity Society of Japan)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-07-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance Test of HTS Superconducting Joint for Persistent Current Operation of REBCO Coil\",\"authors\":\"Kohki Takahashi, S. Awaji\",\"doi\":\"10.2221/jcsj.55.268\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Synopsis: The superconducting joint is a key technology to achieve persistent current operation for MRI and NMR magnets, thereby enabling to obtain higher resolution and sensitivity. A persistent current system including a superconducting joint, a persistent current switch and a double pancake coil fabricated with a REBCO tape was prepared by Furukawa Electric Co., Ltd. The magnetic-field decay behaviors during persistent current operation were observed in external fields of 0 and 1 T at 20 K. In a self-field, the decay rate of the persistent current excited up to 170 A reached 1.2 ppm/h after operating for five days, corresponding to a resistance of 5.1  10-13 . From the current–voltage characteristics obtained from the magnetic field decay, it was found that the decay behavior of the persistent current is dominated by joint resistance in the case of high-load operation, but dominated by the shielding current in the case of low-load region of the operating current.\",\"PeriodicalId\":143949,\"journal\":{\"name\":\"TEION KOGAKU (Journal of Cryogenics and Superconductivity Society of Japan)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-07-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"TEION KOGAKU (Journal of Cryogenics and Superconductivity Society of Japan)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2221/jcsj.55.268\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"TEION KOGAKU (Journal of Cryogenics and Superconductivity Society of Japan)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2221/jcsj.55.268","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

摘要:超导接头是实现MRI和NMR磁体持续电流运行的关键技术,从而获得更高的分辨率和灵敏度。由古川电机株式会社研制的恒流系统包括超导接头、恒流开关和用REBCO胶带制作的双煎饼线圈。在20 K、0和1 T的外场条件下,观察了持续电流工作时的磁场衰减行为。在自场中,工作5天后,激发至170 a的持续电流的衰减率达到1.2 ppm/h,对应的电阻为5.110-13从磁场衰减得到的电流-电压特性来看,在高负载工作时,持续电流的衰减行为主要受联合电阻的影响,而在工作电流的低负载区域,则主要受屏蔽电流的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Performance Test of HTS Superconducting Joint for Persistent Current Operation of REBCO Coil
Synopsis: The superconducting joint is a key technology to achieve persistent current operation for MRI and NMR magnets, thereby enabling to obtain higher resolution and sensitivity. A persistent current system including a superconducting joint, a persistent current switch and a double pancake coil fabricated with a REBCO tape was prepared by Furukawa Electric Co., Ltd. The magnetic-field decay behaviors during persistent current operation were observed in external fields of 0 and 1 T at 20 K. In a self-field, the decay rate of the persistent current excited up to 170 A reached 1.2 ppm/h after operating for five days, corresponding to a resistance of 5.1  10-13 . From the current–voltage characteristics obtained from the magnetic field decay, it was found that the decay behavior of the persistent current is dominated by joint resistance in the case of high-load operation, but dominated by the shielding current in the case of low-load region of the operating current.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信