介绍一种改进的电站防雷系统

H. Ahmad, L. Ong
{"title":"介绍一种改进的电站防雷系统","authors":"H. Ahmad, L. Ong","doi":"10.1109/IPEC.2005.206980","DOIUrl":null,"url":null,"abstract":"Power stations may face huge losses and damage when struck by lightning. Much effort has been carried out to find an alternative to the conventional lightning air terminal for direct protection to power stations. One of the alternative is to modify the tip configuration of conventional air terminals to enable it to be better inceptor. This paper looks into such possibility by designing and testing different tip configuration air terminals, i.e. sharp, blunt, flat, conical and concave. Tests in high voltage laboratory revealed that blunt air terminal has lower breakdown voltage and longer time to breakdown compared to other air terminals. This suggests that the performance of blunt rod is better than other rods. Based on the laboratory experimental studies, the modification of air terminal geometrical tip could be an alternative for future application specifically for the lightning protection of power stations against direct strokes","PeriodicalId":164802,"journal":{"name":"2005 International Power Engineering Conference","volume":"64 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"An account of a modified lightning protection system for power stations\",\"authors\":\"H. Ahmad, L. Ong\",\"doi\":\"10.1109/IPEC.2005.206980\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Power stations may face huge losses and damage when struck by lightning. Much effort has been carried out to find an alternative to the conventional lightning air terminal for direct protection to power stations. One of the alternative is to modify the tip configuration of conventional air terminals to enable it to be better inceptor. This paper looks into such possibility by designing and testing different tip configuration air terminals, i.e. sharp, blunt, flat, conical and concave. Tests in high voltage laboratory revealed that blunt air terminal has lower breakdown voltage and longer time to breakdown compared to other air terminals. This suggests that the performance of blunt rod is better than other rods. Based on the laboratory experimental studies, the modification of air terminal geometrical tip could be an alternative for future application specifically for the lightning protection of power stations against direct strokes\",\"PeriodicalId\":164802,\"journal\":{\"name\":\"2005 International Power Engineering Conference\",\"volume\":\"64 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-11-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2005 International Power Engineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IPEC.2005.206980\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2005 International Power Engineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPEC.2005.206980","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

当被雷击时,发电站可能面临巨大的损失和破坏。为寻找一种替代传统的防雷空气端子直接保护电站的方法,已经进行了大量的努力。一种替代方案是修改传统航空终端的尖端配置,使其成为更好的接收器。本文通过对尖形、钝形、平形、锥形、凹形等不同末端形态的设计和试验,探讨了这种可能性。高压实验室试验表明,钝型空气端子击穿电压较低,击穿时间较长。这说明钝棒的性能优于其他棒。基于实验室实验研究,改进空气端子的几何尖端可以作为未来应用的一种替代方案,特别是用于电站的直接雷击防雷
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An account of a modified lightning protection system for power stations
Power stations may face huge losses and damage when struck by lightning. Much effort has been carried out to find an alternative to the conventional lightning air terminal for direct protection to power stations. One of the alternative is to modify the tip configuration of conventional air terminals to enable it to be better inceptor. This paper looks into such possibility by designing and testing different tip configuration air terminals, i.e. sharp, blunt, flat, conical and concave. Tests in high voltage laboratory revealed that blunt air terminal has lower breakdown voltage and longer time to breakdown compared to other air terminals. This suggests that the performance of blunt rod is better than other rods. Based on the laboratory experimental studies, the modification of air terminal geometrical tip could be an alternative for future application specifically for the lightning protection of power stations against direct strokes
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信