三相四线制并联有源电力滤波器

E. Fabrício, C. Jacobina, G. A. A. Carlos, M. Corrêa
{"title":"三相四线制并联有源电力滤波器","authors":"E. Fabrício, C. Jacobina, G. A. A. Carlos, M. Corrêa","doi":"10.1109/APEC.2016.7468393","DOIUrl":null,"url":null,"abstract":"This paper proposes a shunt active power filter (SAPF) composed of four H-bridge converters. Each of them is connected by means of isolation transformers. Compared to conventional topologies, the proposed converter permits reducing: dc-link voltage rating, grid current harmonic distortion and/or switching frequency (switching losses). A suitable control strategy to adjust the filter currents as well as dc-link voltage are presented. Two PWM strategies are designed to command the converter according to the reference voltage provided by the controllers. Simulation and experimental results are presented in order to validate theoretical approaches.","PeriodicalId":143091,"journal":{"name":"2016 IEEE Applied Power Electronics Conference and Exposition (APEC)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2016-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Four H-bridge based shunt active power filter for three-phase four wire system\",\"authors\":\"E. Fabrício, C. Jacobina, G. A. A. Carlos, M. Corrêa\",\"doi\":\"10.1109/APEC.2016.7468393\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a shunt active power filter (SAPF) composed of four H-bridge converters. Each of them is connected by means of isolation transformers. Compared to conventional topologies, the proposed converter permits reducing: dc-link voltage rating, grid current harmonic distortion and/or switching frequency (switching losses). A suitable control strategy to adjust the filter currents as well as dc-link voltage are presented. Two PWM strategies are designed to command the converter according to the reference voltage provided by the controllers. Simulation and experimental results are presented in order to validate theoretical approaches.\",\"PeriodicalId\":143091,\"journal\":{\"name\":\"2016 IEEE Applied Power Electronics Conference and Exposition (APEC)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-03-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE Applied Power Electronics Conference and Exposition (APEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APEC.2016.7468393\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Applied Power Electronics Conference and Exposition (APEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC.2016.7468393","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

提出了一种由4个h桥变换器组成的并联型有源电力滤波器。它们之间通过隔离变压器相互连接。与传统拓扑结构相比,所提出的转换器允许降低:直流链路额定电压,电网电流谐波失真和/或开关频率(开关损耗)。提出了一种合适的控制策略来调节滤波器电流和直流电压。设计了两种PWM策略,根据控制器提供的参考电压命令转换器。为了验证理论方法,给出了仿真和实验结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Four H-bridge based shunt active power filter for three-phase four wire system
This paper proposes a shunt active power filter (SAPF) composed of four H-bridge converters. Each of them is connected by means of isolation transformers. Compared to conventional topologies, the proposed converter permits reducing: dc-link voltage rating, grid current harmonic distortion and/or switching frequency (switching losses). A suitable control strategy to adjust the filter currents as well as dc-link voltage are presented. Two PWM strategies are designed to command the converter according to the reference voltage provided by the controllers. Simulation and experimental results are presented in order to validate theoretical approaches.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信