被动微流控混合器的研究

P. Chiarot, R. Mrad, P. Sullivan
{"title":"被动微流控混合器的研究","authors":"P. Chiarot, R. Mrad, P. Sullivan","doi":"10.1109/ICMENS.2004.23","DOIUrl":null,"url":null,"abstract":"Three designs of passive microfluidic mixers (fabricated using Micralyne Protolyne technology on a glass substrate) are studied and compared to a basic straight channel diffusion mixer. The designs are analyzed under continuous and pulsating flow conditions using numerical and experimental tools; specifically finite element analysis and particle image velocimetry. Testing and analysis are performed at pressures that can be generated using reciprocating membrane micropumps integrated into a Micro Total Analysis System. It is determined that one of the proposed mixer concepts outperforms all of the other designs considered and enhanced mixing is achieved under pulsating flow. Performance is judged based on criteria that describes the amount of mixing performed, the concentration uniformity at the outlet of the mixer, and the net flow rate. Recommendations are made on how to improve the overall performance of the passive micromixers.","PeriodicalId":344661,"journal":{"name":"2004 International Conference on MEMS, NANO and Smart Systems (ICMENS'04)","volume":"88 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"A Study of Passive Microfluidic Mixers\",\"authors\":\"P. Chiarot, R. Mrad, P. Sullivan\",\"doi\":\"10.1109/ICMENS.2004.23\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Three designs of passive microfluidic mixers (fabricated using Micralyne Protolyne technology on a glass substrate) are studied and compared to a basic straight channel diffusion mixer. The designs are analyzed under continuous and pulsating flow conditions using numerical and experimental tools; specifically finite element analysis and particle image velocimetry. Testing and analysis are performed at pressures that can be generated using reciprocating membrane micropumps integrated into a Micro Total Analysis System. It is determined that one of the proposed mixer concepts outperforms all of the other designs considered and enhanced mixing is achieved under pulsating flow. Performance is judged based on criteria that describes the amount of mixing performed, the concentration uniformity at the outlet of the mixer, and the net flow rate. Recommendations are made on how to improve the overall performance of the passive micromixers.\",\"PeriodicalId\":344661,\"journal\":{\"name\":\"2004 International Conference on MEMS, NANO and Smart Systems (ICMENS'04)\",\"volume\":\"88 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-08-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2004 International Conference on MEMS, NANO and Smart Systems (ICMENS'04)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICMENS.2004.23\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2004 International Conference on MEMS, NANO and Smart Systems (ICMENS'04)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICMENS.2004.23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

研究了三种被动式微流控混合器的设计(在玻璃基板上采用微流控protoolyne技术制造),并与基本直通道扩散混合器进行了比较。利用数值和实验工具对连续流和脉动流条件下的设计进行了分析;特别是有限元分析和粒子图像测速。测试和分析是在压力下进行的,可以使用集成在微全分析系统中的往复膜微泵产生压力。确定提出的混合器概念之一优于所有考虑的其他设计,并且在脉动流下实现了增强的混合。性能是根据描述混合量、混合器出口浓度均匀性和净流量的标准来判断的。对如何提高无源微混频器的整体性能提出了建议。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Study of Passive Microfluidic Mixers
Three designs of passive microfluidic mixers (fabricated using Micralyne Protolyne technology on a glass substrate) are studied and compared to a basic straight channel diffusion mixer. The designs are analyzed under continuous and pulsating flow conditions using numerical and experimental tools; specifically finite element analysis and particle image velocimetry. Testing and analysis are performed at pressures that can be generated using reciprocating membrane micropumps integrated into a Micro Total Analysis System. It is determined that one of the proposed mixer concepts outperforms all of the other designs considered and enhanced mixing is achieved under pulsating flow. Performance is judged based on criteria that describes the amount of mixing performed, the concentration uniformity at the outlet of the mixer, and the net flow rate. Recommendations are made on how to improve the overall performance of the passive micromixers.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信