m2a锥度金属对金属衔接的短期效果。

A. Lombardi, T. Mallory, M. Alexiades, J. Cuckler, P. Faris, K. Jaffe, E. Keating, C. Nelson, C. Ranawat, J. Williams, R. Wixson, J. Hartman, S. Capps, C. Kefauver
{"title":"m2a锥度金属对金属衔接的短期效果。","authors":"A. Lombardi, T. Mallory, M. Alexiades, J. Cuckler, P. Faris, K. Jaffe, E. Keating, C. Nelson, C. Ranawat, J. Williams, R. Wixson, J. Hartman, S. Capps, C. Kefauver","doi":"10.1054/ARTH.2001.29307","DOIUrl":null,"url":null,"abstract":"A polyethylene-free, metal-on-metal acetabular system (M2a-taper [Biomet, Inc., Warsaw, IN]) was designed in an effort to improve total hip arthroplasty (THA) longevity. Minimum 2-year follow-up results involving 72 polyethylene liner THAs and 78 metal liner THAs from a multicenter, randomized, controlled, investigational device exemption study are reported. Mean Harris hip scores of 95.54 (polyethylene liner group) and 95.23 (metal liner group) were reported at mean follow-up intervals of 3.29 and 3.23 years. Radiographic evaluation revealed no evidence of early failure. No acetabular components have been revised or are pending revision. No statistically significant differences in the data were calculated between liner types except for the immediate postoperative (P=.0415) and minimum 2-year follow-up (P=.0341) angles of inclination. The M2a-taper metal-on-metal articulation may represent a viable alternative for THA in younger, higher demand patients.","PeriodicalId":280050,"journal":{"name":"The Journal of arthroplasty","volume":"121 3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"45","resultStr":"{\"title\":\"Short-term results of the M2a-taper metal-on-metal articulation.\",\"authors\":\"A. Lombardi, T. Mallory, M. Alexiades, J. Cuckler, P. Faris, K. Jaffe, E. Keating, C. Nelson, C. Ranawat, J. Williams, R. Wixson, J. Hartman, S. Capps, C. Kefauver\",\"doi\":\"10.1054/ARTH.2001.29307\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A polyethylene-free, metal-on-metal acetabular system (M2a-taper [Biomet, Inc., Warsaw, IN]) was designed in an effort to improve total hip arthroplasty (THA) longevity. Minimum 2-year follow-up results involving 72 polyethylene liner THAs and 78 metal liner THAs from a multicenter, randomized, controlled, investigational device exemption study are reported. Mean Harris hip scores of 95.54 (polyethylene liner group) and 95.23 (metal liner group) were reported at mean follow-up intervals of 3.29 and 3.23 years. Radiographic evaluation revealed no evidence of early failure. No acetabular components have been revised or are pending revision. No statistically significant differences in the data were calculated between liner types except for the immediate postoperative (P=.0415) and minimum 2-year follow-up (P=.0341) angles of inclination. The M2a-taper metal-on-metal articulation may represent a viable alternative for THA in younger, higher demand patients.\",\"PeriodicalId\":280050,\"journal\":{\"name\":\"The Journal of arthroplasty\",\"volume\":\"121 3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"45\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Journal of arthroplasty\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1054/ARTH.2001.29307\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of arthroplasty","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1054/ARTH.2001.29307","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 45

摘要

一种无聚乙烯、金属对金属的髋臼系统(m2a -锥度[Biomet, Inc., Warsaw, IN])被设计用于提高全髋关节置换术(THA)的寿命。报道了来自多中心、随机、对照、研究性器械豁免研究的72例聚乙烯内衬tha和78例金属内衬tha至少2年的随访结果。Harris髋关节平均评分为95.54(聚乙烯衬套组)和95.23(金属衬套组),平均随访时间为3.29年和3.23年。影像学检查未发现早期衰竭的证据。没有髋臼部件被修改或待修改。除了术后即刻(P= 0.0415)和最小2年随访(P= 0.0341)倾斜角外,两种类型间的数据没有统计学差异。m2a锥形金属对金属关节可能是年轻、高需求患者THA的可行选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Short-term results of the M2a-taper metal-on-metal articulation.
A polyethylene-free, metal-on-metal acetabular system (M2a-taper [Biomet, Inc., Warsaw, IN]) was designed in an effort to improve total hip arthroplasty (THA) longevity. Minimum 2-year follow-up results involving 72 polyethylene liner THAs and 78 metal liner THAs from a multicenter, randomized, controlled, investigational device exemption study are reported. Mean Harris hip scores of 95.54 (polyethylene liner group) and 95.23 (metal liner group) were reported at mean follow-up intervals of 3.29 and 3.23 years. Radiographic evaluation revealed no evidence of early failure. No acetabular components have been revised or are pending revision. No statistically significant differences in the data were calculated between liner types except for the immediate postoperative (P=.0415) and minimum 2-year follow-up (P=.0341) angles of inclination. The M2a-taper metal-on-metal articulation may represent a viable alternative for THA in younger, higher demand patients.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信