C. Xian, Duan Xiongying, Chen Jianhua, Liao Minfu, Z. Jiyan
{"title":"基于Ansoft的混合式断路器静电场分布分析","authors":"C. Xian, Duan Xiongying, Chen Jianhua, Liao Minfu, Z. Jiyan","doi":"10.1109/DEIV.2012.6412458","DOIUrl":null,"url":null,"abstract":"Hybrid circuit breaker (HCB) based on the series of vacuum interrupter and SF6 interrupter uses strong interruption capacity of vacuum and the linear insulation property of SF6 gas to be a high-voltage and high-current breaker. The numerical calculation of 3D electric field is an important way to analyze reasonable and optimization of its structure. The 3D model of the vacuum interrupter and SF6 interrupter are established; the internal electric field distribution of vacuum interrupter and SF6 interrupter are calculated by Ansoft software, and their self-capacitances are solved. Then a 3D computational model of HCB based on models of vacuum interrupter and SF6 interrupter is established, and the distribution characteristics of its electric field are analyzed. The simulation result of electric field distribution of HCB is obtained, and the structure of HCB is optimized designed. It provides a theoretical basis for the structural design of the experimental prototype of HCB.","PeriodicalId":130964,"journal":{"name":"2012 25th International Symposium on Discharges and Electrical Insulation in Vacuum (ISDEIV)","volume":"67 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Static electric field distribution of hybrid circuit breaker based on Ansoft\",\"authors\":\"C. Xian, Duan Xiongying, Chen Jianhua, Liao Minfu, Z. Jiyan\",\"doi\":\"10.1109/DEIV.2012.6412458\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Hybrid circuit breaker (HCB) based on the series of vacuum interrupter and SF6 interrupter uses strong interruption capacity of vacuum and the linear insulation property of SF6 gas to be a high-voltage and high-current breaker. The numerical calculation of 3D electric field is an important way to analyze reasonable and optimization of its structure. The 3D model of the vacuum interrupter and SF6 interrupter are established; the internal electric field distribution of vacuum interrupter and SF6 interrupter are calculated by Ansoft software, and their self-capacitances are solved. Then a 3D computational model of HCB based on models of vacuum interrupter and SF6 interrupter is established, and the distribution characteristics of its electric field are analyzed. The simulation result of electric field distribution of HCB is obtained, and the structure of HCB is optimized designed. It provides a theoretical basis for the structural design of the experimental prototype of HCB.\",\"PeriodicalId\":130964,\"journal\":{\"name\":\"2012 25th International Symposium on Discharges and Electrical Insulation in Vacuum (ISDEIV)\",\"volume\":\"67 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 25th International Symposium on Discharges and Electrical Insulation in Vacuum (ISDEIV)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DEIV.2012.6412458\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 25th International Symposium on Discharges and Electrical Insulation in Vacuum (ISDEIV)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DEIV.2012.6412458","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Static electric field distribution of hybrid circuit breaker based on Ansoft
Hybrid circuit breaker (HCB) based on the series of vacuum interrupter and SF6 interrupter uses strong interruption capacity of vacuum and the linear insulation property of SF6 gas to be a high-voltage and high-current breaker. The numerical calculation of 3D electric field is an important way to analyze reasonable and optimization of its structure. The 3D model of the vacuum interrupter and SF6 interrupter are established; the internal electric field distribution of vacuum interrupter and SF6 interrupter are calculated by Ansoft software, and their self-capacitances are solved. Then a 3D computational model of HCB based on models of vacuum interrupter and SF6 interrupter is established, and the distribution characteristics of its electric field are analyzed. The simulation result of electric field distribution of HCB is obtained, and the structure of HCB is optimized designed. It provides a theoretical basis for the structural design of the experimental prototype of HCB.