用线性逼近和曲线对齐评价心源性猝死指标

R. L. Avitia, M. Reyna, M. Bravo, L. A. Cetto
{"title":"用线性逼近和曲线对齐评价心源性猝死指标","authors":"R. L. Avitia, M. Reyna, M. Bravo, L. A. Cetto","doi":"10.1109/PAHCE.2012.6233426","DOIUrl":null,"url":null,"abstract":"Ventricular Late Potentials make QRS complexes larger, that is why many algorithms are based on quantifying increases in the QRS complex duration. These elongations generate misalignments in the QRS, resulting in practice; the averaged algorithm considers the ECG components, including those VLPs, as well as random variables. We recorded High Resolution ECGs (HRECGs) from 50 subjects in resting position with no heart-stroke antecedents. VLPs were simulated added to the HRECGs, and then two cases were evaluated: (1) duration of the QRS complexes with VLPs without QRS-alignment, and (2) duration of QRS complexes with VLPs using time- and amplitude- QRS-alignment. When using amplitude- and time-alignment it is possible to reach a sensitivity of 0.96 and a specificity of 0.52, as opposed to 0.72 and 0.40, respectively, when using only SAECG without QRS-alignment.","PeriodicalId":255935,"journal":{"name":"2012 Pan American Health Care Exchanges","volume":"53 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-03-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of a sudden cardiac death indicator using linear approximation and curves alignment\",\"authors\":\"R. L. Avitia, M. Reyna, M. Bravo, L. A. Cetto\",\"doi\":\"10.1109/PAHCE.2012.6233426\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Ventricular Late Potentials make QRS complexes larger, that is why many algorithms are based on quantifying increases in the QRS complex duration. These elongations generate misalignments in the QRS, resulting in practice; the averaged algorithm considers the ECG components, including those VLPs, as well as random variables. We recorded High Resolution ECGs (HRECGs) from 50 subjects in resting position with no heart-stroke antecedents. VLPs were simulated added to the HRECGs, and then two cases were evaluated: (1) duration of the QRS complexes with VLPs without QRS-alignment, and (2) duration of QRS complexes with VLPs using time- and amplitude- QRS-alignment. When using amplitude- and time-alignment it is possible to reach a sensitivity of 0.96 and a specificity of 0.52, as opposed to 0.72 and 0.40, respectively, when using only SAECG without QRS-alignment.\",\"PeriodicalId\":255935,\"journal\":{\"name\":\"2012 Pan American Health Care Exchanges\",\"volume\":\"53 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-03-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 Pan American Health Care Exchanges\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PAHCE.2012.6233426\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 Pan American Health Care Exchanges","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PAHCE.2012.6233426","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

心室晚电位使QRS复合体变大,这就是为什么许多算法是基于量化QRS复合体持续时间的增加。这些拉长在QRS中产生错位,导致实践;平均算法考虑心电分量,包括那些vlp,以及随机变量。我们记录了50名受试者在静止体位时的高分辨率心电图(hrecg)。在hrecg中模拟VLPs,然后对两种情况进行评估:(1)未与VLPs对齐的QRS复合物的持续时间;(2)使用时间和振幅- QRS对齐的VLPs复合物的持续时间。当使用振幅和时间对准时,可能达到0.96的灵敏度和0.52的特异性,而当只使用SAECG而不使用qrs对准时,分别为0.72和0.40。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of a sudden cardiac death indicator using linear approximation and curves alignment
Ventricular Late Potentials make QRS complexes larger, that is why many algorithms are based on quantifying increases in the QRS complex duration. These elongations generate misalignments in the QRS, resulting in practice; the averaged algorithm considers the ECG components, including those VLPs, as well as random variables. We recorded High Resolution ECGs (HRECGs) from 50 subjects in resting position with no heart-stroke antecedents. VLPs were simulated added to the HRECGs, and then two cases were evaluated: (1) duration of the QRS complexes with VLPs without QRS-alignment, and (2) duration of QRS complexes with VLPs using time- and amplitude- QRS-alignment. When using amplitude- and time-alignment it is possible to reach a sensitivity of 0.96 and a specificity of 0.52, as opposed to 0.72 and 0.40, respectively, when using only SAECG without QRS-alignment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信