Wenting Li, Z. Long, J. Fan, K. Hu, Shaobo Liu, Ming Li
{"title":"用于追溯的脉冲电压校准器稳定性优化研究","authors":"Wenting Li, Z. Long, J. Fan, K. Hu, Shaobo Liu, Ming Li","doi":"10.1109/CICED50259.2021.9556782","DOIUrl":null,"url":null,"abstract":"Impulse Voltage Calibrator is important equipment in traceability of impulse voltage measurement. The characteristic of impulse voltage calibrator directly affects the accuracy and reliability of impulse voltage measurement. The output voltage parameters of standard calibrator will be changed after long-term operation. In order to optimize the stability and reduce the temperature rise of the calibrator, constant temperature control scheme of impulse calibrator is proposed. The parameters of (1.56/60) μs calibrator were selected to study. The results show that the long-term stability parameters of the standard impulse voltage source are improved by 0.04% and the accuracy of impulse voltage traceability is effectively improved after temperature control of the temperature.","PeriodicalId":221387,"journal":{"name":"2021 China International Conference on Electricity Distribution (CICED)","volume":"120 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Research on Optimizing the Stability of Impulse Voltage Calibrator used in Traceability\",\"authors\":\"Wenting Li, Z. Long, J. Fan, K. Hu, Shaobo Liu, Ming Li\",\"doi\":\"10.1109/CICED50259.2021.9556782\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Impulse Voltage Calibrator is important equipment in traceability of impulse voltage measurement. The characteristic of impulse voltage calibrator directly affects the accuracy and reliability of impulse voltage measurement. The output voltage parameters of standard calibrator will be changed after long-term operation. In order to optimize the stability and reduce the temperature rise of the calibrator, constant temperature control scheme of impulse calibrator is proposed. The parameters of (1.56/60) μs calibrator were selected to study. The results show that the long-term stability parameters of the standard impulse voltage source are improved by 0.04% and the accuracy of impulse voltage traceability is effectively improved after temperature control of the temperature.\",\"PeriodicalId\":221387,\"journal\":{\"name\":\"2021 China International Conference on Electricity Distribution (CICED)\",\"volume\":\"120 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-04-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 China International Conference on Electricity Distribution (CICED)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CICED50259.2021.9556782\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 China International Conference on Electricity Distribution (CICED)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CICED50259.2021.9556782","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Research on Optimizing the Stability of Impulse Voltage Calibrator used in Traceability
Impulse Voltage Calibrator is important equipment in traceability of impulse voltage measurement. The characteristic of impulse voltage calibrator directly affects the accuracy and reliability of impulse voltage measurement. The output voltage parameters of standard calibrator will be changed after long-term operation. In order to optimize the stability and reduce the temperature rise of the calibrator, constant temperature control scheme of impulse calibrator is proposed. The parameters of (1.56/60) μs calibrator were selected to study. The results show that the long-term stability parameters of the standard impulse voltage source are improved by 0.04% and the accuracy of impulse voltage traceability is effectively improved after temperature control of the temperature.