Julio Fredy Chura Acero, Wilhem R. Limachi Viamonte, O. C. Velasquez, Henry Shuta Lloclla
{"title":"库皮尼克风电场及THD对并网的影响。80mw的案例研究","authors":"Julio Fredy Chura Acero, Wilhem R. Limachi Viamonte, O. C. Velasquez, Henry Shuta Lloclla","doi":"10.1109/ISGTLatinAmerica52371.2021.9543049","DOIUrl":null,"url":null,"abstract":"This article analyzes the impact of the integration of large-scale wind generation in an Electric Power System, also the problem of the aeolian generation is described regarding to the quality of the produced energy because the inverters, that distort the fundamental wave of tension and current, has been incorporate like one of the characteristics of the aeolian generation that use turbines of variable speed, together with the exports and imports of reactive power and the consequent decrease of the power factor; for this purpose takes a practical example, with real measures of reactive powers, power factor and harmonics, carried out in the Demonstrative Wind Farm of Cupisnique and others accumulated measures from the records of the technical documentation of the wind farm, exposing a methodology to determine, with the realized measures, the values of reactive powers, power factor and harmonics for each value of load degree of the wind farm and operation of the turbines.","PeriodicalId":120262,"journal":{"name":"2021 IEEE PES Innovative Smart Grid Technologies Conference - Latin America (ISGT Latin America)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Cupisnique Wind Power Plant and the Effect of THD on the Connection to the Grid. Case Study for 80 MW\",\"authors\":\"Julio Fredy Chura Acero, Wilhem R. Limachi Viamonte, O. C. Velasquez, Henry Shuta Lloclla\",\"doi\":\"10.1109/ISGTLatinAmerica52371.2021.9543049\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This article analyzes the impact of the integration of large-scale wind generation in an Electric Power System, also the problem of the aeolian generation is described regarding to the quality of the produced energy because the inverters, that distort the fundamental wave of tension and current, has been incorporate like one of the characteristics of the aeolian generation that use turbines of variable speed, together with the exports and imports of reactive power and the consequent decrease of the power factor; for this purpose takes a practical example, with real measures of reactive powers, power factor and harmonics, carried out in the Demonstrative Wind Farm of Cupisnique and others accumulated measures from the records of the technical documentation of the wind farm, exposing a methodology to determine, with the realized measures, the values of reactive powers, power factor and harmonics for each value of load degree of the wind farm and operation of the turbines.\",\"PeriodicalId\":120262,\"journal\":{\"name\":\"2021 IEEE PES Innovative Smart Grid Technologies Conference - Latin America (ISGT Latin America)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-09-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE PES Innovative Smart Grid Technologies Conference - Latin America (ISGT Latin America)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISGTLatinAmerica52371.2021.9543049\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE PES Innovative Smart Grid Technologies Conference - Latin America (ISGT Latin America)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGTLatinAmerica52371.2021.9543049","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Cupisnique Wind Power Plant and the Effect of THD on the Connection to the Grid. Case Study for 80 MW
This article analyzes the impact of the integration of large-scale wind generation in an Electric Power System, also the problem of the aeolian generation is described regarding to the quality of the produced energy because the inverters, that distort the fundamental wave of tension and current, has been incorporate like one of the characteristics of the aeolian generation that use turbines of variable speed, together with the exports and imports of reactive power and the consequent decrease of the power factor; for this purpose takes a practical example, with real measures of reactive powers, power factor and harmonics, carried out in the Demonstrative Wind Farm of Cupisnique and others accumulated measures from the records of the technical documentation of the wind farm, exposing a methodology to determine, with the realized measures, the values of reactive powers, power factor and harmonics for each value of load degree of the wind farm and operation of the turbines.