{"title":"基于灰狼优化技术的不对称故障去除及总谐波畸变分析","authors":"Sandeep Kaur","doi":"10.1109/ICIRCA51532.2021.9544728","DOIUrl":null,"url":null,"abstract":"In this Research paper the Author has obtained results through the use of MATLAB SIMULATION which shows that when a new optimization technique called Grey Wolf is applied on Distribution Static Compensator (D-STATCOM), it leads to further improved results for voltage sag and current swell for the three phase fault, double line to ground fault and single line to ground fault. To remove the Total Harmonic Distortion in Distribution System, a new optimization Technique called Grey Wolf Optimization (GWO) has been introduced. The results obtained after using GWO are very encouraging and it has further reduced voltage sag and current swell in the distribution system.","PeriodicalId":245244,"journal":{"name":"2021 Third International Conference on Inventive Research in Computing Applications (ICIRCA)","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-09-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Removal of Unsymmetrical faults and Analysis of Total Harmonic Distortion by using Grey Wolf Optimization Technique\",\"authors\":\"Sandeep Kaur\",\"doi\":\"10.1109/ICIRCA51532.2021.9544728\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this Research paper the Author has obtained results through the use of MATLAB SIMULATION which shows that when a new optimization technique called Grey Wolf is applied on Distribution Static Compensator (D-STATCOM), it leads to further improved results for voltage sag and current swell for the three phase fault, double line to ground fault and single line to ground fault. To remove the Total Harmonic Distortion in Distribution System, a new optimization Technique called Grey Wolf Optimization (GWO) has been introduced. The results obtained after using GWO are very encouraging and it has further reduced voltage sag and current swell in the distribution system.\",\"PeriodicalId\":245244,\"journal\":{\"name\":\"2021 Third International Conference on Inventive Research in Computing Applications (ICIRCA)\",\"volume\":\"12 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-09-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 Third International Conference on Inventive Research in Computing Applications (ICIRCA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIRCA51532.2021.9544728\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 Third International Conference on Inventive Research in Computing Applications (ICIRCA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIRCA51532.2021.9544728","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Removal of Unsymmetrical faults and Analysis of Total Harmonic Distortion by using Grey Wolf Optimization Technique
In this Research paper the Author has obtained results through the use of MATLAB SIMULATION which shows that when a new optimization technique called Grey Wolf is applied on Distribution Static Compensator (D-STATCOM), it leads to further improved results for voltage sag and current swell for the three phase fault, double line to ground fault and single line to ground fault. To remove the Total Harmonic Distortion in Distribution System, a new optimization Technique called Grey Wolf Optimization (GWO) has been introduced. The results obtained after using GWO are very encouraging and it has further reduced voltage sag and current swell in the distribution system.