{"title":"环氧树脂气腔局部放电的脉冲分析","authors":"M. Henriksen","doi":"10.1109/EIC.1982.7464440","DOIUrl":null,"url":null,"abstract":"An investigation was made on samples of unfilled cured epoxy resins containing artificialy made but naturally formed spherical cavities under such an electrical AC-stress that partial discharges occurred.","PeriodicalId":422317,"journal":{"name":"1982 IEEE International Conference on Electrical Insulation","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1982-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Pulse analysis on partial discharges in gas filled cavities in epoxy resins\",\"authors\":\"M. Henriksen\",\"doi\":\"10.1109/EIC.1982.7464440\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An investigation was made on samples of unfilled cured epoxy resins containing artificialy made but naturally formed spherical cavities under such an electrical AC-stress that partial discharges occurred.\",\"PeriodicalId\":422317,\"journal\":{\"name\":\"1982 IEEE International Conference on Electrical Insulation\",\"volume\":\"15 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1982-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1982 IEEE International Conference on Electrical Insulation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EIC.1982.7464440\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1982 IEEE International Conference on Electrical Insulation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EIC.1982.7464440","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Pulse analysis on partial discharges in gas filled cavities in epoxy resins
An investigation was made on samples of unfilled cured epoxy resins containing artificialy made but naturally formed spherical cavities under such an electrical AC-stress that partial discharges occurred.