EBT半自动除颤器的能量产生与放电

J. Melgoza, H. S. Aparicio, Richard A. Ortiz
{"title":"EBT半自动除颤器的能量产生与放电","authors":"J. Melgoza, H. S. Aparicio, Richard A. Ortiz","doi":"10.1109/CERMA.2006.49","DOIUrl":null,"url":null,"abstract":"In this work the main consideration of the design of truncated biphasic exponential external defibrillator appear. The equipment is directed to the treatment of cardiac arrest by ventricular fibrillation. The structure of the defibrillator account with two main processes: the charge stage and the discharge stage. For the charge stage is used a flyback topology controlled to constant frequency with a current sensor in primary and a voltage sensor in secondary of the flyback transformer. The energy is stored in a bank of capacitors in a time from 6 to 15 sec., according to the defibrillators charge standards. For the discharge stage a H bridge is proposed to handle to high voltages with commercial devices. H Bridge allows to generate the biphasic exponential truncated waveform and to modulate the energy. The results of the proposed approach in a prototype of small signal appear","PeriodicalId":179210,"journal":{"name":"Electronics, Robotics and Automotive Mechanics Conference (CERMA'06)","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Energy Generation and Discharge for a Semiautomatic Defibrillator EBT\",\"authors\":\"J. Melgoza, H. S. Aparicio, Richard A. Ortiz\",\"doi\":\"10.1109/CERMA.2006.49\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this work the main consideration of the design of truncated biphasic exponential external defibrillator appear. The equipment is directed to the treatment of cardiac arrest by ventricular fibrillation. The structure of the defibrillator account with two main processes: the charge stage and the discharge stage. For the charge stage is used a flyback topology controlled to constant frequency with a current sensor in primary and a voltage sensor in secondary of the flyback transformer. The energy is stored in a bank of capacitors in a time from 6 to 15 sec., according to the defibrillators charge standards. For the discharge stage a H bridge is proposed to handle to high voltages with commercial devices. H Bridge allows to generate the biphasic exponential truncated waveform and to modulate the energy. The results of the proposed approach in a prototype of small signal appear\",\"PeriodicalId\":179210,\"journal\":{\"name\":\"Electronics, Robotics and Automotive Mechanics Conference (CERMA'06)\",\"volume\":\"11 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-09-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Electronics, Robotics and Automotive Mechanics Conference (CERMA'06)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CERMA.2006.49\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electronics, Robotics and Automotive Mechanics Conference (CERMA'06)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CERMA.2006.49","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本文主要介绍了截断型双相指数型体外除颤器的设计思路。该设备用于治疗由心室颤动引起的心脏骤停。除颤器的结构主要有两个过程:充电阶段和放电阶段。充电级采用反激拓扑结构,控制频率恒定,反激变压器的一次电流传感器和二次电压传感器。根据除颤器充电标准,能量在6到15秒的时间内存储在一组电容器中。在放电阶段,建议采用H桥,用商用装置处理高压。H桥允许产生双相指数截断波形和调制能量。在一个小信号的原型上给出了该方法的结果
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Energy Generation and Discharge for a Semiautomatic Defibrillator EBT
In this work the main consideration of the design of truncated biphasic exponential external defibrillator appear. The equipment is directed to the treatment of cardiac arrest by ventricular fibrillation. The structure of the defibrillator account with two main processes: the charge stage and the discharge stage. For the charge stage is used a flyback topology controlled to constant frequency with a current sensor in primary and a voltage sensor in secondary of the flyback transformer. The energy is stored in a bank of capacitors in a time from 6 to 15 sec., according to the defibrillators charge standards. For the discharge stage a H bridge is proposed to handle to high voltages with commercial devices. H Bridge allows to generate the biphasic exponential truncated waveform and to modulate the energy. The results of the proposed approach in a prototype of small signal appear
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信