J. Andle, J. T. Weaver, J. Vetelino, D. McAllister
{"title":"单向换能器在声板型生物传感器中的应用","authors":"J. Andle, J. T. Weaver, J. Vetelino, D. McAllister","doi":"10.1109/ULTSYM.1993.339473","DOIUrl":null,"url":null,"abstract":"One of the most important issues in acoustic plate mode (APM) sensor design has been the excitation of a single acoustic mode within the APM spectrum. In order to acheive this selective excitation without incurring high triple transit distortions, single phase unidirectional transducers (SPUDT) are employed. Thick aluminum electrodes are used to provide strong mechanical reflections and improve the directivity, hence the phase linearity, of the resulting delay line. A dual delay line oscillator (DDLO) sensor measurement system has been evaluated for the selective detection of double-stranded DNA. The observed frequency shifts indicate an essentially linear, reproducible response to chemically denatured DNA samples up to at least 200 ng/mL. The observed fractional frequency change per unit mass (1/f δF/δm) is -6×10-8 ng-1 of DNA in a 1 mL solution.","PeriodicalId":127770,"journal":{"name":"1993 Proceedings IEEE Ultrasonics Symposium","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Application of unidirectional transducers in acoustic plate mode biosensors\",\"authors\":\"J. Andle, J. T. Weaver, J. Vetelino, D. McAllister\",\"doi\":\"10.1109/ULTSYM.1993.339473\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"One of the most important issues in acoustic plate mode (APM) sensor design has been the excitation of a single acoustic mode within the APM spectrum. In order to acheive this selective excitation without incurring high triple transit distortions, single phase unidirectional transducers (SPUDT) are employed. Thick aluminum electrodes are used to provide strong mechanical reflections and improve the directivity, hence the phase linearity, of the resulting delay line. A dual delay line oscillator (DDLO) sensor measurement system has been evaluated for the selective detection of double-stranded DNA. The observed frequency shifts indicate an essentially linear, reproducible response to chemically denatured DNA samples up to at least 200 ng/mL. The observed fractional frequency change per unit mass (1/f δF/δm) is -6×10-8 ng-1 of DNA in a 1 mL solution.\",\"PeriodicalId\":127770,\"journal\":{\"name\":\"1993 Proceedings IEEE Ultrasonics Symposium\",\"volume\":\"33 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1993 Proceedings IEEE Ultrasonics Symposium\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.1993.339473\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1993 Proceedings IEEE Ultrasonics Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.1993.339473","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
摘要
声板模式(APM)传感器设计中最重要的问题之一是在APM频谱内激发单个声模式。为了实现这种选择性激励而不产生高的三次传输畸变,采用了单相单向换能器(SPUDT)。厚铝电极用于提供强的机械反射,并改善延迟线的指向性,从而提高相位线性度。研究了双延迟线振荡器(dddlo)传感器测量系统在双链DNA选择性检测中的应用。观察到的频移表明,对化学变性DNA样品的响应至少为200ng /mL,基本上是线性的,可重复的。在1ml溶液中,每单位质量(1/f δ f /δm)观察到的分数频率变化是-6倍于10-8 ng-1的DNA。
Application of unidirectional transducers in acoustic plate mode biosensors
One of the most important issues in acoustic plate mode (APM) sensor design has been the excitation of a single acoustic mode within the APM spectrum. In order to acheive this selective excitation without incurring high triple transit distortions, single phase unidirectional transducers (SPUDT) are employed. Thick aluminum electrodes are used to provide strong mechanical reflections and improve the directivity, hence the phase linearity, of the resulting delay line. A dual delay line oscillator (DDLO) sensor measurement system has been evaluated for the selective detection of double-stranded DNA. The observed frequency shifts indicate an essentially linear, reproducible response to chemically denatured DNA samples up to at least 200 ng/mL. The observed fractional frequency change per unit mass (1/f δF/δm) is -6×10-8 ng-1 of DNA in a 1 mL solution.