{"title":"5kv至46kv充水槽挤压电力电缆加速老化试验的IEEE指南","authors":"","doi":"10.1109/IEEESTD.2022.9707747","DOIUrl":null,"url":null,"abstract":"Provided in this guide are information and recommendations on the equipment, cable specimens, test conditions, test control methodologies, measurements, data analysis, and interpretation in performing accelerated aging tests for 5 kV to 46 kV rated cables using water-filled tanks. The accelerated aging tests may be time-to-failure tests and/or tests in which the samples are aged for fixed times followed by diagnostic testing.","PeriodicalId":153478,"journal":{"name":"IEEE Std 1407-2021 (Revision of IEEE Std 1407-2007)","volume":"128 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-02-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"IEEE Guide for Accelerated Aging Tests for 5 kV to 46 kV Extruded Electric Power Cables Using Water-Filled Tanks\",\"authors\":\"\",\"doi\":\"10.1109/IEEESTD.2022.9707747\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Provided in this guide are information and recommendations on the equipment, cable specimens, test conditions, test control methodologies, measurements, data analysis, and interpretation in performing accelerated aging tests for 5 kV to 46 kV rated cables using water-filled tanks. The accelerated aging tests may be time-to-failure tests and/or tests in which the samples are aged for fixed times followed by diagnostic testing.\",\"PeriodicalId\":153478,\"journal\":{\"name\":\"IEEE Std 1407-2021 (Revision of IEEE Std 1407-2007)\",\"volume\":\"128 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-02-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Std 1407-2021 (Revision of IEEE Std 1407-2007)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IEEESTD.2022.9707747\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Std 1407-2021 (Revision of IEEE Std 1407-2007)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEEESTD.2022.9707747","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
IEEE Guide for Accelerated Aging Tests for 5 kV to 46 kV Extruded Electric Power Cables Using Water-Filled Tanks
Provided in this guide are information and recommendations on the equipment, cable specimens, test conditions, test control methodologies, measurements, data analysis, and interpretation in performing accelerated aging tests for 5 kV to 46 kV rated cables using water-filled tanks. The accelerated aging tests may be time-to-failure tests and/or tests in which the samples are aged for fixed times followed by diagnostic testing.