功率因数校正电容系统的抗谐振有源方法

D. Costa, G. Marques, S. Fernando
{"title":"功率因数校正电容系统的抗谐振有源方法","authors":"D. Costa, G. Marques, S. Fernando","doi":"10.1109/SIBIRCON.2008.4602565","DOIUrl":null,"url":null,"abstract":"Since most loads in electrical distribution systems are inductive, power factor correction through the application of capacitors is the natural choice. However, the capacitor installation can create additional problems, because of harmonic pollution and natural resonance. To avoid these problems, this paper proposes a new anti-resonance active system for power capacitors. The proposed active system is composed of a power electronics current converter connected in series with the power factor capacitors. This will ensure that the power capacitors have low harmonic content, avoiding the damage caused by harmonic resonance or distorted utility voltage. Some results are presented in order to show the effectiveness of the proposed system.","PeriodicalId":295946,"journal":{"name":"2008 IEEE Region 8 International Conference on Computational Technologies in Electrical and Electronics Engineering","volume":"50 5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-07-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"An anti-resonance active method for a power factor correction capacitive system\",\"authors\":\"D. Costa, G. Marques, S. Fernando\",\"doi\":\"10.1109/SIBIRCON.2008.4602565\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Since most loads in electrical distribution systems are inductive, power factor correction through the application of capacitors is the natural choice. However, the capacitor installation can create additional problems, because of harmonic pollution and natural resonance. To avoid these problems, this paper proposes a new anti-resonance active system for power capacitors. The proposed active system is composed of a power electronics current converter connected in series with the power factor capacitors. This will ensure that the power capacitors have low harmonic content, avoiding the damage caused by harmonic resonance or distorted utility voltage. Some results are presented in order to show the effectiveness of the proposed system.\",\"PeriodicalId\":295946,\"journal\":{\"name\":\"2008 IEEE Region 8 International Conference on Computational Technologies in Electrical and Electronics Engineering\",\"volume\":\"50 5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-07-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 IEEE Region 8 International Conference on Computational Technologies in Electrical and Electronics Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SIBIRCON.2008.4602565\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 IEEE Region 8 International Conference on Computational Technologies in Electrical and Electronics Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SIBIRCON.2008.4602565","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

由于配电系统中的大多数负载是感性的,因此通过电容器的应用进行功率因数校正是自然的选择。然而,电容器的安装会产生额外的问题,因为谐波污染和自然共振。为了避免这些问题,本文提出了一种新的电力电容器抗谐振有源系统。提出的有源系统由功率因数电容器串联的电力电子电流变换器组成。这将确保电力电容器具有低谐波含量,避免谐波谐振或失真公用电压造成的损坏。为了证明该系统的有效性,给出了一些结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An anti-resonance active method for a power factor correction capacitive system
Since most loads in electrical distribution systems are inductive, power factor correction through the application of capacitors is the natural choice. However, the capacitor installation can create additional problems, because of harmonic pollution and natural resonance. To avoid these problems, this paper proposes a new anti-resonance active system for power capacitors. The proposed active system is composed of a power electronics current converter connected in series with the power factor capacitors. This will ensure that the power capacitors have low harmonic content, avoiding the damage caused by harmonic resonance or distorted utility voltage. Some results are presented in order to show the effectiveness of the proposed system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信