基于决策树技术的负载侵占条件下距离继电器zone3的阻塞

N. Chaudhari, Trupti P. Hinge, S. Dambhare
{"title":"基于决策树技术的负载侵占条件下距离继电器zone3的阻塞","authors":"N. Chaudhari, Trupti P. Hinge, S. Dambhare","doi":"10.1109/POWERI.2016.8077248","DOIUrl":null,"url":null,"abstract":"False tripping of distance relays on load encroachment may lead to cascade tripping and subsequent blackouts. Hence relays should be supervised to avoid tripping on load encroachment. In this paper, an algorithm based on Decision Tree (DT) is proposed for the differentiation of load encroachment from fault. DT is formulated using Transient Stability Margin (TSM) of generator angles as an attribute. The distance relay is supervised with the decision from DT to avoid tripping on load encroachment. Case Studies are presented on IEEE New England 39 bus system using DIgSILENT PowerFactory software. The simulated results proves the effectiveness of the proposed scheme.","PeriodicalId":332286,"journal":{"name":"2016 IEEE 7th Power India International Conference (PIICON)","volume":"1 1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Blocking of distance relays zone3 under load encroachment conditions using decision tree technique\",\"authors\":\"N. Chaudhari, Trupti P. Hinge, S. Dambhare\",\"doi\":\"10.1109/POWERI.2016.8077248\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"False tripping of distance relays on load encroachment may lead to cascade tripping and subsequent blackouts. Hence relays should be supervised to avoid tripping on load encroachment. In this paper, an algorithm based on Decision Tree (DT) is proposed for the differentiation of load encroachment from fault. DT is formulated using Transient Stability Margin (TSM) of generator angles as an attribute. The distance relay is supervised with the decision from DT to avoid tripping on load encroachment. Case Studies are presented on IEEE New England 39 bus system using DIgSILENT PowerFactory software. The simulated results proves the effectiveness of the proposed scheme.\",\"PeriodicalId\":332286,\"journal\":{\"name\":\"2016 IEEE 7th Power India International Conference (PIICON)\",\"volume\":\"1 1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE 7th Power India International Conference (PIICON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/POWERI.2016.8077248\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE 7th Power India International Conference (PIICON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/POWERI.2016.8077248","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

距离继电器在负荷侵占时误跳闸可能导致串级跳闸和随后的停电。因此,应该对继电器进行监督,以避免在负载侵占时跳闸。本文提出了一种基于决策树(DT)的负荷侵占与故障区分算法。DT以发电机角度的暂态稳定裕度(TSM)为属性。用DT的决策来监督距离继电器,以避免在负载侵占时跳闸。介绍了使用DIgSILENT PowerFactory软件对IEEE新英格兰39总线系统进行的实例研究。仿真结果证明了该方案的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Blocking of distance relays zone3 under load encroachment conditions using decision tree technique
False tripping of distance relays on load encroachment may lead to cascade tripping and subsequent blackouts. Hence relays should be supervised to avoid tripping on load encroachment. In this paper, an algorithm based on Decision Tree (DT) is proposed for the differentiation of load encroachment from fault. DT is formulated using Transient Stability Margin (TSM) of generator angles as an attribute. The distance relay is supervised with the decision from DT to avoid tripping on load encroachment. Case Studies are presented on IEEE New England 39 bus system using DIgSILENT PowerFactory software. The simulated results proves the effectiveness of the proposed scheme.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信