Felipe Quintero-Zuluaga, Pablo Viana-Villa, Daniel Giraldo-Gómez, B. Arboleda, D. Villegas, Mauricio Sánchez, Camilo Pérez, N. Duque
{"title":"基于pmu的特殊保护方案的环内硬件设计与测试:以哥伦比亚-厄瓜多尔互联为例","authors":"Felipe Quintero-Zuluaga, Pablo Viana-Villa, Daniel Giraldo-Gómez, B. Arboleda, D. Villegas, Mauricio Sánchez, Camilo Pérez, N. Duque","doi":"10.1109/TDLA47668.2020.9326098","DOIUrl":null,"url":null,"abstract":"The use of established technologies such as synchrophasor measurement and the use of emerging technologies such as Real-Time Digital Simulators -RTS- are gaining relevance in the design and testing of applications associated with the protection of power networks from a systemic point of view. This paper introduces the reasons that led to the decision to renew the Special Protection Scheme -SPS- in charge of separating the Colombian and Ecuadorian power networks in the presence of conditions that threaten the stability of either system. A brief history of the use of synchrophasor measurement in Colombia and several success cases in the implementation of PMU-based SPS worldwide are also given. The proposed protection functions implemented in the new SPS and a novel platform for testing SPS based on the use of Real-Time Digital Systems -RTS- in a Hardware in the Loop scheme -HIL- are described. Finally, lessons learned and conclusions are given.","PeriodicalId":448644,"journal":{"name":"2020 IEEE PES Transmission & Distribution Conference and Exhibition - Latin America (T&D LA)","volume":"113 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Hardware in the Loop Design and Testing of a PMU-Based Special Protection Scheme: Case Study of Colombia-Ecuador Interconnection\",\"authors\":\"Felipe Quintero-Zuluaga, Pablo Viana-Villa, Daniel Giraldo-Gómez, B. Arboleda, D. Villegas, Mauricio Sánchez, Camilo Pérez, N. Duque\",\"doi\":\"10.1109/TDLA47668.2020.9326098\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The use of established technologies such as synchrophasor measurement and the use of emerging technologies such as Real-Time Digital Simulators -RTS- are gaining relevance in the design and testing of applications associated with the protection of power networks from a systemic point of view. This paper introduces the reasons that led to the decision to renew the Special Protection Scheme -SPS- in charge of separating the Colombian and Ecuadorian power networks in the presence of conditions that threaten the stability of either system. A brief history of the use of synchrophasor measurement in Colombia and several success cases in the implementation of PMU-based SPS worldwide are also given. The proposed protection functions implemented in the new SPS and a novel platform for testing SPS based on the use of Real-Time Digital Systems -RTS- in a Hardware in the Loop scheme -HIL- are described. Finally, lessons learned and conclusions are given.\",\"PeriodicalId\":448644,\"journal\":{\"name\":\"2020 IEEE PES Transmission & Distribution Conference and Exhibition - Latin America (T&D LA)\",\"volume\":\"113 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-09-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE PES Transmission & Distribution Conference and Exhibition - Latin America (T&D LA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TDLA47668.2020.9326098\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE PES Transmission & Distribution Conference and Exhibition - Latin America (T&D LA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TDLA47668.2020.9326098","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Hardware in the Loop Design and Testing of a PMU-Based Special Protection Scheme: Case Study of Colombia-Ecuador Interconnection
The use of established technologies such as synchrophasor measurement and the use of emerging technologies such as Real-Time Digital Simulators -RTS- are gaining relevance in the design and testing of applications associated with the protection of power networks from a systemic point of view. This paper introduces the reasons that led to the decision to renew the Special Protection Scheme -SPS- in charge of separating the Colombian and Ecuadorian power networks in the presence of conditions that threaten the stability of either system. A brief history of the use of synchrophasor measurement in Colombia and several success cases in the implementation of PMU-based SPS worldwide are also given. The proposed protection functions implemented in the new SPS and a novel platform for testing SPS based on the use of Real-Time Digital Systems -RTS- in a Hardware in the Loop scheme -HIL- are described. Finally, lessons learned and conclusions are given.