电气化铁路带OPF和机组承诺的高压直流馈电

L. Abrahamsson, S. Ostlund, L. Soder
{"title":"电气化铁路带OPF和机组承诺的高压直流馈电","authors":"L. Abrahamsson, S. Ostlund, L. Soder","doi":"10.1109/ESARS.2012.6387481","DOIUrl":null,"url":null,"abstract":"In this paper a railway power system design based on an HVDC feeder is suggested. The converter stations between the public grid and the HVDC feeder can be sparsely distributed, in the range of 100 km or more, whereas the converters connecting the HVDC feeder to the catenary are distributed with a much closer spacing. The ratings of the catenary-connected ones can be lower than substation transformers or rotary converters, since the power conversion can be fully controlled. Simulations of the proposed solution show clear advantages regarding transmission losses and voltages compared to conventional systems, especially for cases with long catenary sections, and when there are substantial shares of regeneration from the trains.","PeriodicalId":243822,"journal":{"name":"2012 Electrical Systems for Aircraft, Railway and Ship Propulsion","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-12-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"HVDC feeding with OPF and unit commitment for electric railways\",\"authors\":\"L. Abrahamsson, S. Ostlund, L. Soder\",\"doi\":\"10.1109/ESARS.2012.6387481\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper a railway power system design based on an HVDC feeder is suggested. The converter stations between the public grid and the HVDC feeder can be sparsely distributed, in the range of 100 km or more, whereas the converters connecting the HVDC feeder to the catenary are distributed with a much closer spacing. The ratings of the catenary-connected ones can be lower than substation transformers or rotary converters, since the power conversion can be fully controlled. Simulations of the proposed solution show clear advantages regarding transmission losses and voltages compared to conventional systems, especially for cases with long catenary sections, and when there are substantial shares of regeneration from the trains.\",\"PeriodicalId\":243822,\"journal\":{\"name\":\"2012 Electrical Systems for Aircraft, Railway and Ship Propulsion\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-12-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 Electrical Systems for Aircraft, Railway and Ship Propulsion\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ESARS.2012.6387481\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 Electrical Systems for Aircraft, Railway and Ship Propulsion","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ESARS.2012.6387481","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

本文提出了一种基于高压直流馈线的铁路电力系统设计方案。公共电网和高压直流馈线之间的换流站可以稀疏分布,在100公里或更大的范围内,而连接高压直流馈线到接触网的变流器则分布得更近。由于功率转换可以完全控制,因此接触网连接的变压器的额定值可以低于变电站变压器或旋转变流器。模拟表明,与传统系统相比,该解决方案在传输损耗和电压方面具有明显的优势,特别是在长接触网段的情况下,以及当有大量的列车再生时。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
HVDC feeding with OPF and unit commitment for electric railways
In this paper a railway power system design based on an HVDC feeder is suggested. The converter stations between the public grid and the HVDC feeder can be sparsely distributed, in the range of 100 km or more, whereas the converters connecting the HVDC feeder to the catenary are distributed with a much closer spacing. The ratings of the catenary-connected ones can be lower than substation transformers or rotary converters, since the power conversion can be fully controlled. Simulations of the proposed solution show clear advantages regarding transmission losses and voltages compared to conventional systems, especially for cases with long catenary sections, and when there are substantial shares of regeneration from the trains.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信