竞争电力市场中无功电源的最佳配置和无功电力采购方法

B. Tyagi, S. Srivastava
{"title":"竞争电力市场中无功电源的最佳配置和无功电力采购方法","authors":"B. Tyagi, S. Srivastava","doi":"10.1109/POWERI.2006.1632558","DOIUrl":null,"url":null,"abstract":"In this paper, an approach to select the optimal location and proper size of the reactive power sources has been proposed, based on technical as well as economic criteria. A loss sensitivity index (LSI) has been used to initially select a possible group of buses, where the reactive support is required. Then, an optimal reactive power dispatch (ORPD) algorithm has been developed to select the buses, from this group, based on the economic criteria. An ORPD algorithm has been proposed to procure the reactive power required by the system, at given load condition. The proposed scheme of reactive source placement and reactive power procurement has been tested on IEEE 14-bus and 75-bus Indian power systems","PeriodicalId":191301,"journal":{"name":"2006 IEEE Power India Conference","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"A method for optimal placement of reactive sources & reactive power procurement in competitive electricity markets\",\"authors\":\"B. Tyagi, S. Srivastava\",\"doi\":\"10.1109/POWERI.2006.1632558\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, an approach to select the optimal location and proper size of the reactive power sources has been proposed, based on technical as well as economic criteria. A loss sensitivity index (LSI) has been used to initially select a possible group of buses, where the reactive support is required. Then, an optimal reactive power dispatch (ORPD) algorithm has been developed to select the buses, from this group, based on the economic criteria. An ORPD algorithm has been proposed to procure the reactive power required by the system, at given load condition. The proposed scheme of reactive source placement and reactive power procurement has been tested on IEEE 14-bus and 75-bus Indian power systems\",\"PeriodicalId\":191301,\"journal\":{\"name\":\"2006 IEEE Power India Conference\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-06-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 IEEE Power India Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/POWERI.2006.1632558\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE Power India Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/POWERI.2006.1632558","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

本文从技术和经济的角度出发,提出了一种选择无功电源的最佳位置和大小的方法。损耗灵敏度指数(LSI)已被用于最初选择一组可能的总线,其中需要无功支持。在此基础上,提出了一种基于经济性标准的最优无功调度算法(ORPD)。提出了一种在给定负载条件下获取系统所需无功功率的ORPD算法。该方案已在IEEE 14总线和75总线印度电力系统上进行了测试
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A method for optimal placement of reactive sources & reactive power procurement in competitive electricity markets
In this paper, an approach to select the optimal location and proper size of the reactive power sources has been proposed, based on technical as well as economic criteria. A loss sensitivity index (LSI) has been used to initially select a possible group of buses, where the reactive support is required. Then, an optimal reactive power dispatch (ORPD) algorithm has been developed to select the buses, from this group, based on the economic criteria. An ORPD algorithm has been proposed to procure the reactive power required by the system, at given load condition. The proposed scheme of reactive source placement and reactive power procurement has been tested on IEEE 14-bus and 75-bus Indian power systems
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信