用于动物行为实验的植入式神经肌肉刺激器

Sha Hong, Wang Yan, Ren Chaoshi
{"title":"用于动物行为实验的植入式神经肌肉刺激器","authors":"Sha Hong, Wang Yan, Ren Chaoshi","doi":"10.1109/ICNIC.2005.1499872","DOIUrl":null,"url":null,"abstract":"The design of implantable neuromuscular stimulator used in the behavior experiments desires that the stimulator has maximum functionality to meet the need of the implanted device, such as small size, reliable, safe and easy to use. In this thesis, we consider the basic problem above and two types devices of the stimulator are developed. The first device developed uses standard CMOS IC, and it can provide bipolar interval pulse sequence as electrical stimulation in order to avoid the effect of direct current The function of the second device is specified by software rather than by silicon hardware, allowing a single device to be programmed for different functions. The two devices have been successfully used in animal experiments, especially on rat's experiments.","PeriodicalId":169717,"journal":{"name":"Proceedings. 2005 First International Conference on Neural Interface and Control, 2005.","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-05-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Implantable neuromuscular stimulators used in animal behavior experiments\",\"authors\":\"Sha Hong, Wang Yan, Ren Chaoshi\",\"doi\":\"10.1109/ICNIC.2005.1499872\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The design of implantable neuromuscular stimulator used in the behavior experiments desires that the stimulator has maximum functionality to meet the need of the implanted device, such as small size, reliable, safe and easy to use. In this thesis, we consider the basic problem above and two types devices of the stimulator are developed. The first device developed uses standard CMOS IC, and it can provide bipolar interval pulse sequence as electrical stimulation in order to avoid the effect of direct current The function of the second device is specified by software rather than by silicon hardware, allowing a single device to be programmed for different functions. The two devices have been successfully used in animal experiments, especially on rat's experiments.\",\"PeriodicalId\":169717,\"journal\":{\"name\":\"Proceedings. 2005 First International Conference on Neural Interface and Control, 2005.\",\"volume\":\"9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-05-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings. 2005 First International Conference on Neural Interface and Control, 2005.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICNIC.2005.1499872\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings. 2005 First International Conference on Neural Interface and Control, 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICNIC.2005.1499872","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

用于行为实验的植入式神经肌肉刺激器的设计要求刺激器具有最大的功能以满足植入装置的需要,如体积小、可靠、安全、使用方便等。在本文中,我们考虑了上述基本问题,并开发了两种类型的刺激器装置。开发的第一个器件使用标准的CMOS IC,它可以提供双极间隔脉冲序列作为电刺激,以避免直流电的影响。第二个器件的功能由软件指定,而不是由硅硬件指定,允许单个器件编程不同的功能。这两种装置已成功地应用于动物实验,特别是大鼠实验。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Implantable neuromuscular stimulators used in animal behavior experiments
The design of implantable neuromuscular stimulator used in the behavior experiments desires that the stimulator has maximum functionality to meet the need of the implanted device, such as small size, reliable, safe and easy to use. In this thesis, we consider the basic problem above and two types devices of the stimulator are developed. The first device developed uses standard CMOS IC, and it can provide bipolar interval pulse sequence as electrical stimulation in order to avoid the effect of direct current The function of the second device is specified by software rather than by silicon hardware, allowing a single device to be programmed for different functions. The two devices have been successfully used in animal experiments, especially on rat's experiments.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信