电极放置对硅导联心电图形态的影响

K. Gillette, M. Gsell, A. Prassl, G. Plank
{"title":"电极放置对硅导联心电图形态的影响","authors":"K. Gillette, M. Gsell, A. Prassl, G. Plank","doi":"10.23919/cinc53138.2021.9662705","DOIUrl":null,"url":null,"abstract":"Introduction: Multiple clinical studies have aimed to assess the influence of electrode placement on 12 lead electrocardiogram (ECG) morphology. However, a study has not yet been conducted in silico. We therefore aim to systemically investigate the influence of electrode positioning on the morphology of the 12 lead ECG using a cardiac model of electrophysiology under both healthy sinus rhythm and right bundle branch block (RBBB). Methods: A biophysically-detailed model of ventricular electrophysiology of a single subject was used to model body surface potential maps during healthy sinus rhythm and RBBB. A systematic automatic perturbation of all electrodes from the original subject configuration was performed to replicate clinical variation. For each variation in electrode placement, the 12 lead ECG was computed under both conditions. Quantitative differences were assessed using a time-averaged normalized $L_{2}$ norm. Results: The precordial leads that lie in closer proximity to the heart, primarily V2 and V3, experienced the largest morphological changes from vertical electrode movement. Morphological variation in the augmented Goldberger and Einthoven leads resulted predominantly from LA electrode placement. The possibility of a false diagnosis of RBBB during sinus rhythm due to improper electrode placement was also demonstrated.","PeriodicalId":126746,"journal":{"name":"2021 Computing in Cardiology (CinC)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Influence of Electrode Placement on the Morphology of In Silico 12 Lead Electrocardiograms\",\"authors\":\"K. Gillette, M. Gsell, A. Prassl, G. Plank\",\"doi\":\"10.23919/cinc53138.2021.9662705\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: Multiple clinical studies have aimed to assess the influence of electrode placement on 12 lead electrocardiogram (ECG) morphology. However, a study has not yet been conducted in silico. We therefore aim to systemically investigate the influence of electrode positioning on the morphology of the 12 lead ECG using a cardiac model of electrophysiology under both healthy sinus rhythm and right bundle branch block (RBBB). Methods: A biophysically-detailed model of ventricular electrophysiology of a single subject was used to model body surface potential maps during healthy sinus rhythm and RBBB. A systematic automatic perturbation of all electrodes from the original subject configuration was performed to replicate clinical variation. For each variation in electrode placement, the 12 lead ECG was computed under both conditions. Quantitative differences were assessed using a time-averaged normalized $L_{2}$ norm. Results: The precordial leads that lie in closer proximity to the heart, primarily V2 and V3, experienced the largest morphological changes from vertical electrode movement. Morphological variation in the augmented Goldberger and Einthoven leads resulted predominantly from LA electrode placement. The possibility of a false diagnosis of RBBB during sinus rhythm due to improper electrode placement was also demonstrated.\",\"PeriodicalId\":126746,\"journal\":{\"name\":\"2021 Computing in Cardiology (CinC)\",\"volume\":\"22 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-09-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 Computing in Cardiology (CinC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/cinc53138.2021.9662705\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 Computing in Cardiology (CinC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/cinc53138.2021.9662705","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

多项临床研究旨在评估电极放置对12导联心电图(ECG)形态的影响。然而,一项研究尚未在计算机上进行。因此,我们的目的是系统地研究电极定位对12导联心电图形态学的影响,采用健康窦性心律和右束支阻滞(RBBB)下的心脏电生理模型。方法:采用单个受试者的生物物理详细的心室电生理模型来模拟健康窦性心律和RBBB期间的体表电位图。从原始受试者配置的所有电极进行系统的自动扰动,以复制临床变化。对于电极放置的每一个变化,在两种情况下计算12导联心电图。采用时间平均归一化$L_{2}$ norm评估定量差异。结果:离心脏较近的心前导联,主要是V2和V3,在垂直电极运动中形态变化最大。在Goldberger和Einthoven增强的导联中,形态学变化主要是由LA电极放置引起的。在窦性心律期间,由于电极放置不当,可能会误诊RBBB。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Influence of Electrode Placement on the Morphology of In Silico 12 Lead Electrocardiograms
Introduction: Multiple clinical studies have aimed to assess the influence of electrode placement on 12 lead electrocardiogram (ECG) morphology. However, a study has not yet been conducted in silico. We therefore aim to systemically investigate the influence of electrode positioning on the morphology of the 12 lead ECG using a cardiac model of electrophysiology under both healthy sinus rhythm and right bundle branch block (RBBB). Methods: A biophysically-detailed model of ventricular electrophysiology of a single subject was used to model body surface potential maps during healthy sinus rhythm and RBBB. A systematic automatic perturbation of all electrodes from the original subject configuration was performed to replicate clinical variation. For each variation in electrode placement, the 12 lead ECG was computed under both conditions. Quantitative differences were assessed using a time-averaged normalized $L_{2}$ norm. Results: The precordial leads that lie in closer proximity to the heart, primarily V2 and V3, experienced the largest morphological changes from vertical electrode movement. Morphological variation in the augmented Goldberger and Einthoven leads resulted predominantly from LA electrode placement. The possibility of a false diagnosis of RBBB during sinus rhythm due to improper electrode placement was also demonstrated.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信