{"title":"联合电气Meramec工厂二氧化硫脱除系统的历史。","authors":"G E Dreifke, J F McLaughlin, J D Smith","doi":"10.1080/00139307509435865","DOIUrl":null,"url":null,"abstract":"<p><p>In line with the then emerging air pollution control regulations Union Electric installed a limestone injection wet scrubber sulfur dioxide removal system on an intermediate size coal-fired utility boiler at its Meramec Power Plant on an experimental basis in September, 1968. Approximately 3 years of operation many difficulties were encountered with plugging and scaling of various system components by calcium sulphate. As a result of this experience along with related experiences by other utilities employing similar systems, the experiment was terminated in June, 1971. As a result of the experiences gained, however, second generation experiments in sulfur dioxide removal have been initiated elsewhere with the hope of improved performance. A number of experimental projects are still under tests. Costs in resources, reliability, and disposal of residual by-products are matters of great concern. The ture cost of sulfur dioxide removal systems in dollars and resources is not well known and perhaps a reevaluation of current and future SO2 removal projects is in order at this time before additional resources are committed.</p>","PeriodicalId":11979,"journal":{"name":"Environmental letters","volume":"9 4","pages":"395-403"},"PeriodicalIF":0.0000,"publicationDate":"1975-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/00139307509435865","citationCount":"0","resultStr":"{\"title\":\"History of SO2 removal system at the Meramec plant of union electric.\",\"authors\":\"G E Dreifke, J F McLaughlin, J D Smith\",\"doi\":\"10.1080/00139307509435865\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In line with the then emerging air pollution control regulations Union Electric installed a limestone injection wet scrubber sulfur dioxide removal system on an intermediate size coal-fired utility boiler at its Meramec Power Plant on an experimental basis in September, 1968. Approximately 3 years of operation many difficulties were encountered with plugging and scaling of various system components by calcium sulphate. As a result of this experience along with related experiences by other utilities employing similar systems, the experiment was terminated in June, 1971. As a result of the experiences gained, however, second generation experiments in sulfur dioxide removal have been initiated elsewhere with the hope of improved performance. A number of experimental projects are still under tests. Costs in resources, reliability, and disposal of residual by-products are matters of great concern. The ture cost of sulfur dioxide removal systems in dollars and resources is not well known and perhaps a reevaluation of current and future SO2 removal projects is in order at this time before additional resources are committed.</p>\",\"PeriodicalId\":11979,\"journal\":{\"name\":\"Environmental letters\",\"volume\":\"9 4\",\"pages\":\"395-403\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1975-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/00139307509435865\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Environmental letters\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/00139307509435865\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Environmental letters","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/00139307509435865","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
History of SO2 removal system at the Meramec plant of union electric.
In line with the then emerging air pollution control regulations Union Electric installed a limestone injection wet scrubber sulfur dioxide removal system on an intermediate size coal-fired utility boiler at its Meramec Power Plant on an experimental basis in September, 1968. Approximately 3 years of operation many difficulties were encountered with plugging and scaling of various system components by calcium sulphate. As a result of this experience along with related experiences by other utilities employing similar systems, the experiment was terminated in June, 1971. As a result of the experiences gained, however, second generation experiments in sulfur dioxide removal have been initiated elsewhere with the hope of improved performance. A number of experimental projects are still under tests. Costs in resources, reliability, and disposal of residual by-products are matters of great concern. The ture cost of sulfur dioxide removal systems in dollars and resources is not well known and perhaps a reevaluation of current and future SO2 removal projects is in order at this time before additional resources are committed.