麻醉效果中心房颤动的小波方差差异

R. Cervigón, F. Castells, J. Moreno, J. Mateo, C. Sánchez, J. Millet
{"title":"麻醉效果中心房颤动的小波方差差异","authors":"R. Cervigón, F. Castells, J. Moreno, J. Mateo, C. Sánchez, J. Millet","doi":"10.1109/CIC.2008.4749118","DOIUrl":null,"url":null,"abstract":"Effect of anaesthetic agents in restoration rhythm procedures during atrial fibrillation (AF) has not been fully investigated. We evaluated the effects of a widely used anaesthetic agent (propofol) in the fibrillation patterns. Intra-atrial recordings belong to 18 patients diagnosed with AF were analyzed ldquobeforerdquo (baseline) and ldquoduringrdquo anaesthetic infusion. The goal of this study is to characterize the variation in atrial properties along the atria in both states. The wavelet variance decomposes the variance of a time series on a scale by scale basis and hence has considerable appeal when physical phenomena are analyzed in terms of variations operating over a range of different scales. Moreover, the variance estimates are more accurately determined with a maximal-overlap version of the wavelet transform (MODWT). As mother wavelet was used the Haar wavelet where the signal was partitioned over seven scales. Wavelet analysis highlights a significant lower changes during the anaesthetic infusion respect to the basal conditions in the right atrium, with an opposite effect and non significant values in the left atrium. The proposed methodology provides an additional approach to the understanding of the role of the anaesthetic, showing a decrease in the variance inter-scales during the anaesthetic infusion in the right atrium, with the opposite effect in the left atrium.","PeriodicalId":194782,"journal":{"name":"2008 Computers in Cardiology","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Wavelet variance differences in atrial fibrillation during anaesthetic effect\",\"authors\":\"R. Cervigón, F. Castells, J. Moreno, J. Mateo, C. Sánchez, J. Millet\",\"doi\":\"10.1109/CIC.2008.4749118\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Effect of anaesthetic agents in restoration rhythm procedures during atrial fibrillation (AF) has not been fully investigated. We evaluated the effects of a widely used anaesthetic agent (propofol) in the fibrillation patterns. Intra-atrial recordings belong to 18 patients diagnosed with AF were analyzed ldquobeforerdquo (baseline) and ldquoduringrdquo anaesthetic infusion. The goal of this study is to characterize the variation in atrial properties along the atria in both states. The wavelet variance decomposes the variance of a time series on a scale by scale basis and hence has considerable appeal when physical phenomena are analyzed in terms of variations operating over a range of different scales. Moreover, the variance estimates are more accurately determined with a maximal-overlap version of the wavelet transform (MODWT). As mother wavelet was used the Haar wavelet where the signal was partitioned over seven scales. Wavelet analysis highlights a significant lower changes during the anaesthetic infusion respect to the basal conditions in the right atrium, with an opposite effect and non significant values in the left atrium. The proposed methodology provides an additional approach to the understanding of the role of the anaesthetic, showing a decrease in the variance inter-scales during the anaesthetic infusion in the right atrium, with the opposite effect in the left atrium.\",\"PeriodicalId\":194782,\"journal\":{\"name\":\"2008 Computers in Cardiology\",\"volume\":\"42 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 Computers in Cardiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIC.2008.4749118\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 Computers in Cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.2008.4749118","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

麻醉药物在心房颤动(AF)恢复节律过程中的作用尚未得到充分的研究。我们评估了一种广泛使用的麻醉剂(异丙酚)对纤颤模式的影响。分析18例诊断为房颤的患者在麻醉前(基线)和麻醉输注期间的房内记录。本研究的目的是表征心房性质的变化沿心房在两种状态。小波方差在一个尺度的基础上分解时间序列的方差,因此当物理现象在不同尺度范围内的变化进行分析时,小波方差具有相当大的吸引力。此外,使用小波变换的最大重叠版本(MODWT)可以更准确地确定方差估计。当母小波被使用时,哈尔小波将信号划分为七个尺度。小波分析显示,麻醉输注期间右心房的基础情况变化明显较低,而左心房的影响相反,且值不显著。所提出的方法为理解麻醉剂的作用提供了另一种方法,显示在右心房麻醉输注期间,各量表间方差减少,而在左心房则相反。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Wavelet variance differences in atrial fibrillation during anaesthetic effect
Effect of anaesthetic agents in restoration rhythm procedures during atrial fibrillation (AF) has not been fully investigated. We evaluated the effects of a widely used anaesthetic agent (propofol) in the fibrillation patterns. Intra-atrial recordings belong to 18 patients diagnosed with AF were analyzed ldquobeforerdquo (baseline) and ldquoduringrdquo anaesthetic infusion. The goal of this study is to characterize the variation in atrial properties along the atria in both states. The wavelet variance decomposes the variance of a time series on a scale by scale basis and hence has considerable appeal when physical phenomena are analyzed in terms of variations operating over a range of different scales. Moreover, the variance estimates are more accurately determined with a maximal-overlap version of the wavelet transform (MODWT). As mother wavelet was used the Haar wavelet where the signal was partitioned over seven scales. Wavelet analysis highlights a significant lower changes during the anaesthetic infusion respect to the basal conditions in the right atrium, with an opposite effect and non significant values in the left atrium. The proposed methodology provides an additional approach to the understanding of the role of the anaesthetic, showing a decrease in the variance inter-scales during the anaesthetic infusion in the right atrium, with the opposite effect in the left atrium.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信