交流市电口至通信口电磁噪声传输特性研究

T. Tominaga, Y. Akiyama, H. Yamane, N. Kuwabara
{"title":"交流市电口至通信口电磁噪声传输特性研究","authors":"T. Tominaga, Y. Akiyama, H. Yamane, N. Kuwabara","doi":"10.1109/ISEMC.2003.1236653","DOIUrl":null,"url":null,"abstract":"A method of evaluating the isolation factor from an AC mains port to a telecommunication port was investigated. Telecommunication equipment was represented by a 4-port network consisting of a pair of wire and ground. The relationship between input and output signals of the network was represented by an F-matrix and the isolation factor (ratio of input to output signals) was derived from the matrix. We developed a method of measuring the parameters and the measured values for a resistance-network agree well with calculated ones. The evaluation results of the isolation factor for three types of telecommunication equipment show that isolation for differential-mode noise from AC mains to telecommunication ports is larger than that for common-mode noise.","PeriodicalId":359422,"journal":{"name":"2003 IEEE Symposium on Electromagnetic Compatibility. Symposium Record (Cat. No.03CH37446)","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Investigation of electromagnetic noise transmission characteristics from AC mains port to telecommunication port\",\"authors\":\"T. Tominaga, Y. Akiyama, H. Yamane, N. Kuwabara\",\"doi\":\"10.1109/ISEMC.2003.1236653\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A method of evaluating the isolation factor from an AC mains port to a telecommunication port was investigated. Telecommunication equipment was represented by a 4-port network consisting of a pair of wire and ground. The relationship between input and output signals of the network was represented by an F-matrix and the isolation factor (ratio of input to output signals) was derived from the matrix. We developed a method of measuring the parameters and the measured values for a resistance-network agree well with calculated ones. The evaluation results of the isolation factor for three types of telecommunication equipment show that isolation for differential-mode noise from AC mains to telecommunication ports is larger than that for common-mode noise.\",\"PeriodicalId\":359422,\"journal\":{\"name\":\"2003 IEEE Symposium on Electromagnetic Compatibility. Symposium Record (Cat. No.03CH37446)\",\"volume\":\"37 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-10-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2003 IEEE Symposium on Electromagnetic Compatibility. Symposium Record (Cat. No.03CH37446)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEMC.2003.1236653\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 IEEE Symposium on Electromagnetic Compatibility. Symposium Record (Cat. No.03CH37446)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.2003.1236653","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

研究了一种评估交流主端口到通信端口隔离系数的方法。电信设备由一对线和地组成的4端口网络表示。网络输入输出信号之间的关系用f矩阵表示,隔离系数(输入输出信号的比率)由矩阵导出。提出了一种测量电阻网络参数的方法,其实测值与计算值吻合较好。对三种通信设备的隔离系数评价结果表明,从交流电源到通信端口的差模噪声的隔离系数大于共模噪声的隔离系数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Investigation of electromagnetic noise transmission characteristics from AC mains port to telecommunication port
A method of evaluating the isolation factor from an AC mains port to a telecommunication port was investigated. Telecommunication equipment was represented by a 4-port network consisting of a pair of wire and ground. The relationship between input and output signals of the network was represented by an F-matrix and the isolation factor (ratio of input to output signals) was derived from the matrix. We developed a method of measuring the parameters and the measured values for a resistance-network agree well with calculated ones. The evaluation results of the isolation factor for three types of telecommunication equipment show that isolation for differential-mode noise from AC mains to telecommunication ports is larger than that for common-mode noise.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信