{"title":"智利电力系统的负荷频率响应","authors":"J. Quiroz, Carlos Fuentes, H. Chávez","doi":"10.1109/SGSMA51733.2022.9806015","DOIUrl":null,"url":null,"abstract":"The current transition from synchronous to power electronics-based generation has led to important concerns in power systems operation, particularly on the reduction of natural frequency response from synchronous machines. These concerns have increased the interest in monitoring and estimating the overall frequency response of power systems, which has been centered in the response of generators that comprises most of system response. However, the load frequency response has been overlooked as its contribution is not as significant as that of generators, and also because of the large amount of individual loads within a power system that are challenging to monitor. This paper reports the load frequency response in the case of Chile, considering SCADA and Syncrophasor data. A set of representative loads is considered to evaluate the frequency response and extrapolate this behavior to assess the overall load frequency response.","PeriodicalId":256954,"journal":{"name":"2022 International Conference on Smart Grid Synchronized Measurements and Analytics (SGSMA)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Load Frequency Response in The Chilean Power System\",\"authors\":\"J. Quiroz, Carlos Fuentes, H. Chávez\",\"doi\":\"10.1109/SGSMA51733.2022.9806015\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The current transition from synchronous to power electronics-based generation has led to important concerns in power systems operation, particularly on the reduction of natural frequency response from synchronous machines. These concerns have increased the interest in monitoring and estimating the overall frequency response of power systems, which has been centered in the response of generators that comprises most of system response. However, the load frequency response has been overlooked as its contribution is not as significant as that of generators, and also because of the large amount of individual loads within a power system that are challenging to monitor. This paper reports the load frequency response in the case of Chile, considering SCADA and Syncrophasor data. A set of representative loads is considered to evaluate the frequency response and extrapolate this behavior to assess the overall load frequency response.\",\"PeriodicalId\":256954,\"journal\":{\"name\":\"2022 International Conference on Smart Grid Synchronized Measurements and Analytics (SGSMA)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-05-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 International Conference on Smart Grid Synchronized Measurements and Analytics (SGSMA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SGSMA51733.2022.9806015\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 International Conference on Smart Grid Synchronized Measurements and Analytics (SGSMA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SGSMA51733.2022.9806015","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Load Frequency Response in The Chilean Power System
The current transition from synchronous to power electronics-based generation has led to important concerns in power systems operation, particularly on the reduction of natural frequency response from synchronous machines. These concerns have increased the interest in monitoring and estimating the overall frequency response of power systems, which has been centered in the response of generators that comprises most of system response. However, the load frequency response has been overlooked as its contribution is not as significant as that of generators, and also because of the large amount of individual loads within a power system that are challenging to monitor. This paper reports the load frequency response in the case of Chile, considering SCADA and Syncrophasor data. A set of representative loads is considered to evaluate the frequency response and extrapolate this behavior to assess the overall load frequency response.