初步经验用薄单节段压导导管测量左心室容积

C. Carlsson, E. Soderqvist, L. Brodin, G. Kallner, J. Hultman, H. Elmqvist, S. Saha
{"title":"初步经验用薄单节段压导导管测量左心室容积","authors":"C. Carlsson, E. Soderqvist, L. Brodin, G. Kallner, J. Hultman, H. Elmqvist, S. Saha","doi":"10.1109/IEMBS.2001.1018858","DOIUrl":null,"url":null,"abstract":"A thin and soft multifunctional catheter was evaluated for the simultaneous real time monitoring of left ventricular volume and pressure with special consideration to side effects such as interference with normal cardiac electrophysiology. In four pigs, pressure and volume were simultaneously recorded by using the thin single segment pressure and conductance catheter. Measurements were done under varied cardiac conditions: at baseline, during preload reduction and afterload increase. Volumes were calibrated with intracardiac ultrasound measurements. During preload reduction the pressure and volume decreased as expected. A cautious afterload increase resulted in a corresponding pressure and volume increase, the maximum of the pressure curve changed from early to late. Both SV and EDV increased. The very few arrhythmias were mainly caused by surgical interference. The present study demonstrates that our thin single segment conductance catheter for the simultaneous measurement of LV volume and pressure has a performance that warrants further development with the goal of making the method available for human use. In particular, the catheter did not cause any arrhythmias.","PeriodicalId":386546,"journal":{"name":"2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":"58 5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Initial experience with a thin single segment pressure and conductance catheter for measurement of left ventricular volume\",\"authors\":\"C. Carlsson, E. Soderqvist, L. Brodin, G. Kallner, J. Hultman, H. Elmqvist, S. Saha\",\"doi\":\"10.1109/IEMBS.2001.1018858\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A thin and soft multifunctional catheter was evaluated for the simultaneous real time monitoring of left ventricular volume and pressure with special consideration to side effects such as interference with normal cardiac electrophysiology. In four pigs, pressure and volume were simultaneously recorded by using the thin single segment pressure and conductance catheter. Measurements were done under varied cardiac conditions: at baseline, during preload reduction and afterload increase. Volumes were calibrated with intracardiac ultrasound measurements. During preload reduction the pressure and volume decreased as expected. A cautious afterload increase resulted in a corresponding pressure and volume increase, the maximum of the pressure curve changed from early to late. Both SV and EDV increased. The very few arrhythmias were mainly caused by surgical interference. The present study demonstrates that our thin single segment conductance catheter for the simultaneous measurement of LV volume and pressure has a performance that warrants further development with the goal of making the method available for human use. In particular, the catheter did not cause any arrhythmias.\",\"PeriodicalId\":386546,\"journal\":{\"name\":\"2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society\",\"volume\":\"58 5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-10-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IEMBS.2001.1018858\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMBS.2001.1018858","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

采用薄软多功能导管同时实时监测左心室容积和压力,并特别考虑干扰正常心脏电生理等副作用。在4头猪中,使用薄的单段压力和传导导管同时记录压力和体积。测量是在不同的心脏条件下进行的:在基线时,在负荷减轻前和负荷增加后。用心内超声测量校准容积。在预压过程中,压力和体积如预期的那样减小。谨慎的后负荷增加导致相应的压力和体积增加,压力曲线的最大值由早到晚变化。SV和EDV均增加。少数心律失常主要由手术干扰引起。目前的研究表明,我们用于同时测量左室体积和压力的薄单段导电导管具有值得进一步发展的性能,目标是使该方法可供人类使用。特别是,导管没有引起任何心律失常。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Initial experience with a thin single segment pressure and conductance catheter for measurement of left ventricular volume
A thin and soft multifunctional catheter was evaluated for the simultaneous real time monitoring of left ventricular volume and pressure with special consideration to side effects such as interference with normal cardiac electrophysiology. In four pigs, pressure and volume were simultaneously recorded by using the thin single segment pressure and conductance catheter. Measurements were done under varied cardiac conditions: at baseline, during preload reduction and afterload increase. Volumes were calibrated with intracardiac ultrasound measurements. During preload reduction the pressure and volume decreased as expected. A cautious afterload increase resulted in a corresponding pressure and volume increase, the maximum of the pressure curve changed from early to late. Both SV and EDV increased. The very few arrhythmias were mainly caused by surgical interference. The present study demonstrates that our thin single segment conductance catheter for the simultaneous measurement of LV volume and pressure has a performance that warrants further development with the goal of making the method available for human use. In particular, the catheter did not cause any arrhythmias.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信