380kv交联聚乙烯电缆系统绝缘可靠性研究

X. Chen, J. Smit, S. Meijer
{"title":"380kv交联聚乙烯电缆系统绝缘可靠性研究","authors":"X. Chen, J. Smit, S. Meijer","doi":"10.1109/EIC.2011.5996193","DOIUrl":null,"url":null,"abstract":"This paper investigates the insulation reliability of 380 kV XLPE cable systems. In order to obtain sufficient service experience of 380 kV XLPE cable systems and detailed failure information, both literature survey and internal interview with several TSO's (Transmission System Operators) in Europe have been carried out. Based on the collected in-service and failure populations regarding insulation, failure rates of 380 kV XLPE cable systems are statistically investigated with a confidence interval, regarding to some uncertainties. The calculated failure rates are compared with those from literatures. It shows that the results that the failure rates from the existing literatures are not suitable for 380 kV XLPE cable systems, because they are dominated by the failures from 220 kV cable systems. The most important consequence for TSO's is forced outage time, therefore these outage time caused by failures is also discussed.","PeriodicalId":129127,"journal":{"name":"2011 Electrical Insulation Conference (EIC).","volume":"349 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Investigation on insulation reliability of 380 kV XLPE cable systems\",\"authors\":\"X. Chen, J. Smit, S. Meijer\",\"doi\":\"10.1109/EIC.2011.5996193\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper investigates the insulation reliability of 380 kV XLPE cable systems. In order to obtain sufficient service experience of 380 kV XLPE cable systems and detailed failure information, both literature survey and internal interview with several TSO's (Transmission System Operators) in Europe have been carried out. Based on the collected in-service and failure populations regarding insulation, failure rates of 380 kV XLPE cable systems are statistically investigated with a confidence interval, regarding to some uncertainties. The calculated failure rates are compared with those from literatures. It shows that the results that the failure rates from the existing literatures are not suitable for 380 kV XLPE cable systems, because they are dominated by the failures from 220 kV cable systems. The most important consequence for TSO's is forced outage time, therefore these outage time caused by failures is also discussed.\",\"PeriodicalId\":129127,\"journal\":{\"name\":\"2011 Electrical Insulation Conference (EIC).\",\"volume\":\"349 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-06-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 Electrical Insulation Conference (EIC).\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EIC.2011.5996193\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 Electrical Insulation Conference (EIC).","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EIC.2011.5996193","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

本文对380kv交联聚乙烯电缆系统的绝缘可靠性进行了研究。为了获得充分的380 kV交联聚乙烯电缆系统的服务经验和详细的故障信息,本文对欧洲几家输电系统运营商(TSO)进行了文献调查和内部访谈。基于收集到的在用绝缘数据和绝缘失效数据,对380 kV交联聚乙烯电缆系统的绝缘故障率进行了统计研究,并在考虑某些不确定性的情况下,给出了置信区间。并将计算的故障率与文献数据进行了比较。结果表明,现有文献的故障率计算结果并不适用于380 kV交联聚乙烯电缆系统,因为它们主要是220 kV电缆系统的故障率。对TSO最重要的影响是强制停运时间,因此对故障引起的停运时间也进行了讨论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Investigation on insulation reliability of 380 kV XLPE cable systems
This paper investigates the insulation reliability of 380 kV XLPE cable systems. In order to obtain sufficient service experience of 380 kV XLPE cable systems and detailed failure information, both literature survey and internal interview with several TSO's (Transmission System Operators) in Europe have been carried out. Based on the collected in-service and failure populations regarding insulation, failure rates of 380 kV XLPE cable systems are statistically investigated with a confidence interval, regarding to some uncertainties. The calculated failure rates are compared with those from literatures. It shows that the results that the failure rates from the existing literatures are not suitable for 380 kV XLPE cable systems, because they are dominated by the failures from 220 kV cable systems. The most important consequence for TSO's is forced outage time, therefore these outage time caused by failures is also discussed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信