{"title":"一种新的呼气酒精分析仪的关键性能筛选应用","authors":"Jonas Ljungblad, B. Hök, M. Ekström","doi":"10.1109/ISSNIP.2014.6827626","DOIUrl":null,"url":null,"abstract":"In screening applications there is a need for improved breath alcohol analyzers. Accuracy, specificity, usability, and through-put are critical to the device performance. Objective: To characterize the critical performance of a new contactless breath alcohol analyzer. Methods: The device is characterized by measurements using artificial breath gas and human subjects. Breath sampling is performed in ambient air using carbon dioxide as a biomarker. Results: Resolution and inter-individual variation, response time, and specificity were shown to meet the requirements of industrial standards. The feasibility of contactless measurement was demonstrated. Conclusions: The new device exhibits sufficient performance in moderately diluted breath samples. Further work is underway to reach the objective of unobtrusive breath alcohol analysis.","PeriodicalId":269784,"journal":{"name":"2014 IEEE Ninth International Conference on Intelligent Sensors, Sensor Networks and Information Processing (ISSNIP)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-04-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":"{\"title\":\"Critical performance of a new breath alcohol analyzer for screening applications\",\"authors\":\"Jonas Ljungblad, B. Hök, M. Ekström\",\"doi\":\"10.1109/ISSNIP.2014.6827626\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In screening applications there is a need for improved breath alcohol analyzers. Accuracy, specificity, usability, and through-put are critical to the device performance. Objective: To characterize the critical performance of a new contactless breath alcohol analyzer. Methods: The device is characterized by measurements using artificial breath gas and human subjects. Breath sampling is performed in ambient air using carbon dioxide as a biomarker. Results: Resolution and inter-individual variation, response time, and specificity were shown to meet the requirements of industrial standards. The feasibility of contactless measurement was demonstrated. Conclusions: The new device exhibits sufficient performance in moderately diluted breath samples. Further work is underway to reach the objective of unobtrusive breath alcohol analysis.\",\"PeriodicalId\":269784,\"journal\":{\"name\":\"2014 IEEE Ninth International Conference on Intelligent Sensors, Sensor Networks and Information Processing (ISSNIP)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-04-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE Ninth International Conference on Intelligent Sensors, Sensor Networks and Information Processing (ISSNIP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISSNIP.2014.6827626\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE Ninth International Conference on Intelligent Sensors, Sensor Networks and Information Processing (ISSNIP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISSNIP.2014.6827626","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Critical performance of a new breath alcohol analyzer for screening applications
In screening applications there is a need for improved breath alcohol analyzers. Accuracy, specificity, usability, and through-put are critical to the device performance. Objective: To characterize the critical performance of a new contactless breath alcohol analyzer. Methods: The device is characterized by measurements using artificial breath gas and human subjects. Breath sampling is performed in ambient air using carbon dioxide as a biomarker. Results: Resolution and inter-individual variation, response time, and specificity were shown to meet the requirements of industrial standards. The feasibility of contactless measurement was demonstrated. Conclusions: The new device exhibits sufficient performance in moderately diluted breath samples. Further work is underway to reach the objective of unobtrusive breath alcohol analysis.