配电系统中为平衡用电而使用的存储系统

D. Motyka, Martina Kajanová, P. Braciník, Marian Tomasov, M. Roch
{"title":"配电系统中为平衡用电而使用的存储系统","authors":"D. Motyka, Martina Kajanová, P. Braciník, Marian Tomasov, M. Roch","doi":"10.1109/IYCE45807.2019.8991561","DOIUrl":null,"url":null,"abstract":"The utilization of the electricity storage into batteries system is increasing. Most batteries are connected at the point in the network where the power of renewable energy sources is produced. These battery storage systems serve primarily to power electricity to households. They are most often used in cooperation with renewable energy sources, especially photovoltaic power plants. When installing renewable sources without using battery storage in distribution networks, there are several problems in the production of electricity from renewable sources. At a time of low power consumption and high electricity generation at the point of connection of renewable energy sources, a change in power flow occurs. The power generated from the sources flows into the distribution network or up to the superior network. If a distribution company installed battery storage at the point of connection, the power from renewable sources would not flow to the rest of the distribution system and would be stored on that distribution network node. Once the capacity size has been correctly determined at a given node, the distribution company could benefit from such solution. The distribution company could lease the capacity of the batteries to customers who have the renewable energy sources to store their produced energy or could cover part of the electricity consumption at the time of lack of production from the renewable energy sources. The paper deals with this issue, the location of battery storage is simulated on a standardized distribution network.","PeriodicalId":226881,"journal":{"name":"2019 7th International Youth Conference on Energy (IYCE)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Utilization of the storage systems in a distribution system to balance the consumption\",\"authors\":\"D. Motyka, Martina Kajanová, P. Braciník, Marian Tomasov, M. Roch\",\"doi\":\"10.1109/IYCE45807.2019.8991561\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The utilization of the electricity storage into batteries system is increasing. Most batteries are connected at the point in the network where the power of renewable energy sources is produced. These battery storage systems serve primarily to power electricity to households. They are most often used in cooperation with renewable energy sources, especially photovoltaic power plants. When installing renewable sources without using battery storage in distribution networks, there are several problems in the production of electricity from renewable sources. At a time of low power consumption and high electricity generation at the point of connection of renewable energy sources, a change in power flow occurs. The power generated from the sources flows into the distribution network or up to the superior network. If a distribution company installed battery storage at the point of connection, the power from renewable sources would not flow to the rest of the distribution system and would be stored on that distribution network node. Once the capacity size has been correctly determined at a given node, the distribution company could benefit from such solution. The distribution company could lease the capacity of the batteries to customers who have the renewable energy sources to store their produced energy or could cover part of the electricity consumption at the time of lack of production from the renewable energy sources. The paper deals with this issue, the location of battery storage is simulated on a standardized distribution network.\",\"PeriodicalId\":226881,\"journal\":{\"name\":\"2019 7th International Youth Conference on Energy (IYCE)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 7th International Youth Conference on Energy (IYCE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IYCE45807.2019.8991561\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 7th International Youth Conference on Energy (IYCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IYCE45807.2019.8991561","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

储能系统在电池系统中的应用越来越广泛。大多数电池都连接在网络中产生可再生能源的地方。这些电池存储系统主要为家庭供电。它们最常与可再生能源,特别是光伏发电厂合作使用。当在配电网中安装可再生能源而不使用电池存储时,可再生能源发电存在几个问题。在可再生能源接入点的低耗电量和高发电量时,会发生潮流变化。电源产生的电力流入配电网或流向上级电网。如果一家配电公司在连接点安装了电池储能系统,那么来自可再生能源的电力就不会流向配电系统的其余部分,而是存储在该配电网络节点上。一旦在给定节点上正确确定了容量大小,分销公司就可以从这种解决方案中受益。分销公司可以将电池的容量出租给拥有可再生能源的客户来储存他们生产的能源,或者可以在可再生能源生产不足时支付部分电力消耗。本文针对这一问题,在一个标准化的配电网上对蓄电池的贮存位置进行了模拟。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Utilization of the storage systems in a distribution system to balance the consumption
The utilization of the electricity storage into batteries system is increasing. Most batteries are connected at the point in the network where the power of renewable energy sources is produced. These battery storage systems serve primarily to power electricity to households. They are most often used in cooperation with renewable energy sources, especially photovoltaic power plants. When installing renewable sources without using battery storage in distribution networks, there are several problems in the production of electricity from renewable sources. At a time of low power consumption and high electricity generation at the point of connection of renewable energy sources, a change in power flow occurs. The power generated from the sources flows into the distribution network or up to the superior network. If a distribution company installed battery storage at the point of connection, the power from renewable sources would not flow to the rest of the distribution system and would be stored on that distribution network node. Once the capacity size has been correctly determined at a given node, the distribution company could benefit from such solution. The distribution company could lease the capacity of the batteries to customers who have the renewable energy sources to store their produced energy or could cover part of the electricity consumption at the time of lack of production from the renewable energy sources. The paper deals with this issue, the location of battery storage is simulated on a standardized distribution network.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信