雷电电流参数对输电线路感应过电压的影响

D. Mestriner, Martino Nicora, R. Procopio, M. Brignone, M. Rossi, F. Delfino, E. Fiori
{"title":"雷电电流参数对输电线路感应过电压的影响","authors":"D. Mestriner, Martino Nicora, R. Procopio, M. Brignone, M. Rossi, F. Delfino, E. Fiori","doi":"10.1109/EEEIC.2019.8783658","DOIUrl":null,"url":null,"abstract":"The lightning induced voltages in a transmission line need the knowledge of many parameters such as the peak current, the return stroke velocity, the front duration, the channel attenuation and distortion. Their variation affect the results in a non-predictable way and only one variation can cause a high computational cost in the computation procedure. This work presents a method, based on a statistical tool that provides an analytical formula linking the maximum voltage induced on a transmission line with the front duration and the return stroke speed. The analysis and the proposed formula is validated with the results provided by a verified coupling code.","PeriodicalId":422977,"journal":{"name":"2019 IEEE International Conference on Environment and Electrical Engineering and 2019 IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&CPS Europe)","volume":"205 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Lightning Current Parameters Effects on the Induced Overvoltages in Transmission Lines\",\"authors\":\"D. Mestriner, Martino Nicora, R. Procopio, M. Brignone, M. Rossi, F. Delfino, E. Fiori\",\"doi\":\"10.1109/EEEIC.2019.8783658\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The lightning induced voltages in a transmission line need the knowledge of many parameters such as the peak current, the return stroke velocity, the front duration, the channel attenuation and distortion. Their variation affect the results in a non-predictable way and only one variation can cause a high computational cost in the computation procedure. This work presents a method, based on a statistical tool that provides an analytical formula linking the maximum voltage induced on a transmission line with the front duration and the return stroke speed. The analysis and the proposed formula is validated with the results provided by a verified coupling code.\",\"PeriodicalId\":422977,\"journal\":{\"name\":\"2019 IEEE International Conference on Environment and Electrical Engineering and 2019 IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&CPS Europe)\",\"volume\":\"205 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-06-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE International Conference on Environment and Electrical Engineering and 2019 IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&CPS Europe)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EEEIC.2019.8783658\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE International Conference on Environment and Electrical Engineering and 2019 IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&CPS Europe)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEEIC.2019.8783658","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

传输线中雷电感应电压需要知道峰值电流、回冲速度、前持续时间、通道衰减和失真等参数。它们的变化对结果的影响是不可预测的,在计算过程中,只有一个变化就会导致很高的计算成本。这项工作提出了一种基于统计工具的方法,该方法提供了将传输线上感应的最大电压与前持续时间和回行程速度联系起来的分析公式。通过一个已验证的耦合代码验证了分析和公式的正确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Lightning Current Parameters Effects on the Induced Overvoltages in Transmission Lines
The lightning induced voltages in a transmission line need the knowledge of many parameters such as the peak current, the return stroke velocity, the front duration, the channel attenuation and distortion. Their variation affect the results in a non-predictable way and only one variation can cause a high computational cost in the computation procedure. This work presents a method, based on a statistical tool that provides an analytical formula linking the maximum voltage induced on a transmission line with the front duration and the return stroke speed. The analysis and the proposed formula is validated with the results provided by a verified coupling code.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信