{"title":"电力电子牵引变压器h桥变换器重构调制容错方法","authors":"N. Zhao, Zedong Zheng, Yongdong Li","doi":"10.1109/ITEC51675.2021.9490127","DOIUrl":null,"url":null,"abstract":"A fault-tolerant method for H-bridge converter in power electronic traction transformer is proposed. This fault-tolerant mothed can ensure safe operation for H-bridge converter under open-circuit fault condition based on modulation reconstruction strategy. The faulty module can still transfer certain power. The influence of open-circuit fault on a single full-bridge circuit is illustrated, and the influence on modulation and PWM voltage is analyzed. Based on the analysis, the fault-tolerant method is given to reconstruct the modulations of both faulty module and normal modules with the change of current direction. Correctness and efficiency are validated through experimentation.","PeriodicalId":339989,"journal":{"name":"2021 IEEE Transportation Electrification Conference & Expo (ITEC)","volume":"16 3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fault-tolerant Method Based on Reconstructed Modulation for H-bridge Converter in Power Electronic Traction Transformer\",\"authors\":\"N. Zhao, Zedong Zheng, Yongdong Li\",\"doi\":\"10.1109/ITEC51675.2021.9490127\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A fault-tolerant method for H-bridge converter in power electronic traction transformer is proposed. This fault-tolerant mothed can ensure safe operation for H-bridge converter under open-circuit fault condition based on modulation reconstruction strategy. The faulty module can still transfer certain power. The influence of open-circuit fault on a single full-bridge circuit is illustrated, and the influence on modulation and PWM voltage is analyzed. Based on the analysis, the fault-tolerant method is given to reconstruct the modulations of both faulty module and normal modules with the change of current direction. Correctness and efficiency are validated through experimentation.\",\"PeriodicalId\":339989,\"journal\":{\"name\":\"2021 IEEE Transportation Electrification Conference & Expo (ITEC)\",\"volume\":\"16 3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-06-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE Transportation Electrification Conference & Expo (ITEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ITEC51675.2021.9490127\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE Transportation Electrification Conference & Expo (ITEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ITEC51675.2021.9490127","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Fault-tolerant Method Based on Reconstructed Modulation for H-bridge Converter in Power Electronic Traction Transformer
A fault-tolerant method for H-bridge converter in power electronic traction transformer is proposed. This fault-tolerant mothed can ensure safe operation for H-bridge converter under open-circuit fault condition based on modulation reconstruction strategy. The faulty module can still transfer certain power. The influence of open-circuit fault on a single full-bridge circuit is illustrated, and the influence on modulation and PWM voltage is analyzed. Based on the analysis, the fault-tolerant method is given to reconstruct the modulations of both faulty module and normal modules with the change of current direction. Correctness and efficiency are validated through experimentation.