{"title":"工频高压测量用均匀场火花隙的校正","authors":"F. M. Bruce","doi":"10.1049/JI-2.1947.0052","DOIUrl":null,"url":null,"abstract":"A calibration is given for spark-gap electrodes designed to ensure that the spark path lies in a uniform field, and it is shown that for all three sizes of electrodes investigated, covering a range of 9 to 315 kV (peak), the sparkover voltages are within 0.2% of the values given by the empirical lawV=24.22S+6.082√SkV (peak) at 20°C and atmospheric pressure of 760 mm Hg, where S is the electrode spacing in centimetres.All observations were made with vertical gaps having the lower electrode connected to earth, and comparative data were obtained for a sphere gap with electrodes 25 cm in diameter. The effects of surrounding objects and of faulty alignment of the electrodes were determined experimentally, and on the basis of these results a number of recommendations are made, giving the limits within which the spark-over voltage is defined by the above equation.","PeriodicalId":307627,"journal":{"name":"Journal of the Institution of Electrical Engineers - Part II: Power Engineering","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1947-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"65","resultStr":"{\"title\":\"Calibration of uniform-field spark-gaps for high-voltage measurement at power frequencies\",\"authors\":\"F. M. Bruce\",\"doi\":\"10.1049/JI-2.1947.0052\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A calibration is given for spark-gap electrodes designed to ensure that the spark path lies in a uniform field, and it is shown that for all three sizes of electrodes investigated, covering a range of 9 to 315 kV (peak), the sparkover voltages are within 0.2% of the values given by the empirical lawV=24.22S+6.082√SkV (peak) at 20°C and atmospheric pressure of 760 mm Hg, where S is the electrode spacing in centimetres.All observations were made with vertical gaps having the lower electrode connected to earth, and comparative data were obtained for a sphere gap with electrodes 25 cm in diameter. The effects of surrounding objects and of faulty alignment of the electrodes were determined experimentally, and on the basis of these results a number of recommendations are made, giving the limits within which the spark-over voltage is defined by the above equation.\",\"PeriodicalId\":307627,\"journal\":{\"name\":\"Journal of the Institution of Electrical Engineers - Part II: Power Engineering\",\"volume\":\"24 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1947-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"65\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Institution of Electrical Engineers - Part II: Power Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1049/JI-2.1947.0052\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Institution of Electrical Engineers - Part II: Power Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1049/JI-2.1947.0052","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 65
摘要
对火花间隙电极进行了校准,以确保火花路径位于均匀场中,结果表明,对于所有三种尺寸的电极,覆盖9至315 kV(峰值)的范围,在20°C和760 mm Hg的大气压下,火花电压在经验定律v =24.22S+6.082√SkV(峰值)给出的值的0.2%以内,其中S为电极间距,单位为厘米。所有的观测都是在下电极与地面连接的垂直间隙中进行的,并获得了直径为25厘米电极的球形间隙的比较数据。通过实验确定了周围物体和电极错误对准的影响,并在这些结果的基础上提出了一些建议,给出了由上述方程定义的火花过电压的限制。
Calibration of uniform-field spark-gaps for high-voltage measurement at power frequencies
A calibration is given for spark-gap electrodes designed to ensure that the spark path lies in a uniform field, and it is shown that for all three sizes of electrodes investigated, covering a range of 9 to 315 kV (peak), the sparkover voltages are within 0.2% of the values given by the empirical lawV=24.22S+6.082√SkV (peak) at 20°C and atmospheric pressure of 760 mm Hg, where S is the electrode spacing in centimetres.All observations were made with vertical gaps having the lower electrode connected to earth, and comparative data were obtained for a sphere gap with electrodes 25 cm in diameter. The effects of surrounding objects and of faulty alignment of the electrodes were determined experimentally, and on the basis of these results a number of recommendations are made, giving the limits within which the spark-over voltage is defined by the above equation.