植入式颈动脉窦电刺激器的设计与仿真

Pinzheng Ni, Haoyang Liu, H. Yuan, Mengqi Cheng, Nan Xiao
{"title":"植入式颈动脉窦电刺激器的设计与仿真","authors":"Pinzheng Ni, Haoyang Liu, H. Yuan, Mengqi Cheng, Nan Xiao","doi":"10.1109/ICMA54519.2022.9856032","DOIUrl":null,"url":null,"abstract":"Studies have shown that the prevalence of adult hypertension in my country is 23.2%, the treatment rate is 40.7%, the control rate is 15.3%, the treatment rate is 37.5%, 60% of patients who are receiving hypertensive treatment Blood pressure did not obtain significant control, including those with refractory hypertension. The carotid sinus electrical stimulation method is a new way to treat hypertension in recent years. Our carotid sinus electrical stimulator includes pulse generation modules, battery management modules, neural electrical signal sampling modules, and wireless communication modules. This paper focuses on the design of the pulse generating module, using the STM32L433 as the core circuit system of the central control unit, which produces an amplitude adjustable, pulse width, flexible, and pulse width-adjustable pulse generating circuit.","PeriodicalId":120073,"journal":{"name":"2022 IEEE International Conference on Mechatronics and Automation (ICMA)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design And Simulation Of Implantable Carotid Sinus Electrical Stimulator\",\"authors\":\"Pinzheng Ni, Haoyang Liu, H. Yuan, Mengqi Cheng, Nan Xiao\",\"doi\":\"10.1109/ICMA54519.2022.9856032\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Studies have shown that the prevalence of adult hypertension in my country is 23.2%, the treatment rate is 40.7%, the control rate is 15.3%, the treatment rate is 37.5%, 60% of patients who are receiving hypertensive treatment Blood pressure did not obtain significant control, including those with refractory hypertension. The carotid sinus electrical stimulation method is a new way to treat hypertension in recent years. Our carotid sinus electrical stimulator includes pulse generation modules, battery management modules, neural electrical signal sampling modules, and wireless communication modules. This paper focuses on the design of the pulse generating module, using the STM32L433 as the core circuit system of the central control unit, which produces an amplitude adjustable, pulse width, flexible, and pulse width-adjustable pulse generating circuit.\",\"PeriodicalId\":120073,\"journal\":{\"name\":\"2022 IEEE International Conference on Mechatronics and Automation (ICMA)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-08-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE International Conference on Mechatronics and Automation (ICMA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICMA54519.2022.9856032\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE International Conference on Mechatronics and Automation (ICMA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICMA54519.2022.9856032","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

研究表明,我国成人高血压患病率为23.2%,治疗率为40.7%,控制率为15.3%,治疗率为37.5%,60%接受高血压治疗的患者血压未得到显著控制,其中包括难治性高血压患者。颈动脉窦电刺激法是近年来治疗高血压的一种新方法。我们的颈动脉窦电刺激器包括脉冲产生模块、电池管理模块、神经电信号采样模块和无线通信模块。本文重点设计了脉冲产生模块,采用STM32L433作为中央控制单元的核心电路系统,产生一个幅度可调、脉宽可调、柔性、脉宽可调的脉冲产生电路。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design And Simulation Of Implantable Carotid Sinus Electrical Stimulator
Studies have shown that the prevalence of adult hypertension in my country is 23.2%, the treatment rate is 40.7%, the control rate is 15.3%, the treatment rate is 37.5%, 60% of patients who are receiving hypertensive treatment Blood pressure did not obtain significant control, including those with refractory hypertension. The carotid sinus electrical stimulation method is a new way to treat hypertension in recent years. Our carotid sinus electrical stimulator includes pulse generation modules, battery management modules, neural electrical signal sampling modules, and wireless communication modules. This paper focuses on the design of the pulse generating module, using the STM32L433 as the core circuit system of the central control unit, which produces an amplitude adjustable, pulse width, flexible, and pulse width-adjustable pulse generating circuit.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信