基于加速度计与肌电数据关联的高精度运动跟踪

P. Faragó, R. Groza, S. Hintea
{"title":"基于加速度计与肌电数据关联的高精度运动跟踪","authors":"P. Faragó, R. Groza, S. Hintea","doi":"10.1109/TSP.2019.8768874","DOIUrl":null,"url":null,"abstract":"Wearable biomedical electronics are a road opener for ubiquitous healthcare. In this context, correlation of biomedical data acquired from different wearable sensors enable remote health monitoring, and eventually diagnosis and treatment. Activity tracking is an important part of remote health monitoring. For this purpose, this paper proposes a novel architecture for an activity tracker, which correlates accelerometer data with lower-limb electromyogram, in order to implement precision movement detection. The purpose of correlating accelerometer data with lower-limb electromyogram was to discriminate user movement, i.e., walking and running, from other type of activities, e.g. jumping, hand balance, etc., which lead to false increments of the step count. Tests carried out with a laboratory proof of concept of the proposed activity monitor validate the proposed architecture.","PeriodicalId":399087,"journal":{"name":"2019 42nd International Conference on Telecommunications and Signal Processing (TSP)","volume":"47 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"High Precision Activity Tracker Based On The Correlation Of Accelerometer And EMG Data\",\"authors\":\"P. Faragó, R. Groza, S. Hintea\",\"doi\":\"10.1109/TSP.2019.8768874\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Wearable biomedical electronics are a road opener for ubiquitous healthcare. In this context, correlation of biomedical data acquired from different wearable sensors enable remote health monitoring, and eventually diagnosis and treatment. Activity tracking is an important part of remote health monitoring. For this purpose, this paper proposes a novel architecture for an activity tracker, which correlates accelerometer data with lower-limb electromyogram, in order to implement precision movement detection. The purpose of correlating accelerometer data with lower-limb electromyogram was to discriminate user movement, i.e., walking and running, from other type of activities, e.g. jumping, hand balance, etc., which lead to false increments of the step count. Tests carried out with a laboratory proof of concept of the proposed activity monitor validate the proposed architecture.\",\"PeriodicalId\":399087,\"journal\":{\"name\":\"2019 42nd International Conference on Telecommunications and Signal Processing (TSP)\",\"volume\":\"47 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 42nd International Conference on Telecommunications and Signal Processing (TSP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TSP.2019.8768874\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 42nd International Conference on Telecommunications and Signal Processing (TSP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TSP.2019.8768874","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

可穿戴生物医学电子设备为无处不在的医疗保健开辟了道路。在这种情况下,从不同的可穿戴传感器获取的生物医学数据的相关性可以实现远程健康监测,并最终实现诊断和治疗。活动跟踪是远程健康监测的重要组成部分。为此,本文提出了一种新的活动跟踪器架构,将加速度计数据与下肢肌电图相关联,以实现精确的运动检测。将加速度计数据与下肢肌电图相关联的目的是将用户的运动(即步行和跑步)与其他类型的活动(如跳跃、手部平衡等)区分开来,这些活动会导致错误的步数增量。使用拟议活动监控器的实验室概念验证进行的测试验证了拟议的体系结构。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
High Precision Activity Tracker Based On The Correlation Of Accelerometer And EMG Data
Wearable biomedical electronics are a road opener for ubiquitous healthcare. In this context, correlation of biomedical data acquired from different wearable sensors enable remote health monitoring, and eventually diagnosis and treatment. Activity tracking is an important part of remote health monitoring. For this purpose, this paper proposes a novel architecture for an activity tracker, which correlates accelerometer data with lower-limb electromyogram, in order to implement precision movement detection. The purpose of correlating accelerometer data with lower-limb electromyogram was to discriminate user movement, i.e., walking and running, from other type of activities, e.g. jumping, hand balance, etc., which lead to false increments of the step count. Tests carried out with a laboratory proof of concept of the proposed activity monitor validate the proposed architecture.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信