交叉验证SAXS和cryo-EM数据

B. Afsari, J. S. Kim, G. Chirikjian
{"title":"交叉验证SAXS和cryo-EM数据","authors":"B. Afsari, J. S. Kim, G. Chirikjian","doi":"10.1109/BIBM.2015.7359856","DOIUrl":null,"url":null,"abstract":"Cryo-Electron Microscopy (EM) and Small Angle X-ray Scattering (SAXS) are two different data acquisition modalities often used to glean information about the structure of large biomolecular complexes in their native states. A SAXS experiment is generally considered fast and easy but unveiling the structure at very low resolution, whereas a cryo-EM experiment needs more extensive preparation and post-acquisition computation to yield a 3D density map at higher resolution. In certain applications, one may need to verify if the data acquired in the SAXS and cryo-EM experiments correspond to the same structure (e.g., prior to reconstructing the 3D density map in EM). In this paper, a simple and fast method is proposed to verify the compatibility of the SAXS and EM experiments. The method is based on averaging the 2D correlation of EM images and the Abel transform of the SAXS data. The results are verified on simulations of conformational states of large biomolecular complexes.","PeriodicalId":186217,"journal":{"name":"2015 IEEE International Conference on Bioinformatics and Biomedicine (BIBM)","volume":"86 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Cross-validation of data in SAXS and cryo-EM\",\"authors\":\"B. Afsari, J. S. Kim, G. Chirikjian\",\"doi\":\"10.1109/BIBM.2015.7359856\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Cryo-Electron Microscopy (EM) and Small Angle X-ray Scattering (SAXS) are two different data acquisition modalities often used to glean information about the structure of large biomolecular complexes in their native states. A SAXS experiment is generally considered fast and easy but unveiling the structure at very low resolution, whereas a cryo-EM experiment needs more extensive preparation and post-acquisition computation to yield a 3D density map at higher resolution. In certain applications, one may need to verify if the data acquired in the SAXS and cryo-EM experiments correspond to the same structure (e.g., prior to reconstructing the 3D density map in EM). In this paper, a simple and fast method is proposed to verify the compatibility of the SAXS and EM experiments. The method is based on averaging the 2D correlation of EM images and the Abel transform of the SAXS data. The results are verified on simulations of conformational states of large biomolecular complexes.\",\"PeriodicalId\":186217,\"journal\":{\"name\":\"2015 IEEE International Conference on Bioinformatics and Biomedicine (BIBM)\",\"volume\":\"86 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-11-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE International Conference on Bioinformatics and Biomedicine (BIBM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BIBM.2015.7359856\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE International Conference on Bioinformatics and Biomedicine (BIBM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIBM.2015.7359856","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

低温电子显微镜(EM)和小角度x射线散射(SAXS)是两种不同的数据采集方式,通常用于收集大型生物分子复合物在其天然状态下的结构信息。SAXS实验通常被认为是快速和简单的,但在非常低的分辨率下揭示了结构,而cro - em实验需要更广泛的准备和采集后计算才能获得更高分辨率的3D密度图。在某些应用中,可能需要验证SAXS和cro -EM实验中获得的数据是否对应于相同的结构(例如,在EM中重建3D密度图之前)。本文提出了一种简单、快速的方法来验证SAXS和EM实验的兼容性。该方法是基于对二维相关图像进行平均,并对SAXS数据进行Abel变换。这些结果在大型生物分子复合物的构象态模拟中得到了验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Cross-validation of data in SAXS and cryo-EM
Cryo-Electron Microscopy (EM) and Small Angle X-ray Scattering (SAXS) are two different data acquisition modalities often used to glean information about the structure of large biomolecular complexes in their native states. A SAXS experiment is generally considered fast and easy but unveiling the structure at very low resolution, whereas a cryo-EM experiment needs more extensive preparation and post-acquisition computation to yield a 3D density map at higher resolution. In certain applications, one may need to verify if the data acquired in the SAXS and cryo-EM experiments correspond to the same structure (e.g., prior to reconstructing the 3D density map in EM). In this paper, a simple and fast method is proposed to verify the compatibility of the SAXS and EM experiments. The method is based on averaging the 2D correlation of EM images and the Abel transform of the SAXS data. The results are verified on simulations of conformational states of large biomolecular complexes.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信