{"title":"基于四探测器和D-T中子源的孔隙度测定新方法","authors":"F. Junting, Z. Feng, Z. Hui, F. Jilin","doi":"10.3997/2214-4609.202113190","DOIUrl":null,"url":null,"abstract":"Summary The sensitivity of D-T neutron porosity logging to formation porosity change is lower than that of Am-Be neutron porosity logging.In order to improve the sensitivity of porosity measurement, based on a measurement system consisting of four detectors and D-T neutron source, The Monte Carlo simulation method was used to establish the numerical calculation model , the effects of density and hydrogen index on the thermal neutron count ratio and inelastic gamma count ratio are studied . A new method to correct the influence of density in porosity measurement by inelastic gamma count ratio is proposed. The data in the model well was processed using this method, and the processed results showed better accuracy and sensitivity to porosity than the unprocessed values.","PeriodicalId":265130,"journal":{"name":"82nd EAGE Annual Conference & Exhibition","volume":"617 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A new determining porosity method based on four detectors and D-T neutron source\",\"authors\":\"F. Junting, Z. Feng, Z. Hui, F. Jilin\",\"doi\":\"10.3997/2214-4609.202113190\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Summary The sensitivity of D-T neutron porosity logging to formation porosity change is lower than that of Am-Be neutron porosity logging.In order to improve the sensitivity of porosity measurement, based on a measurement system consisting of four detectors and D-T neutron source, The Monte Carlo simulation method was used to establish the numerical calculation model , the effects of density and hydrogen index on the thermal neutron count ratio and inelastic gamma count ratio are studied . A new method to correct the influence of density in porosity measurement by inelastic gamma count ratio is proposed. The data in the model well was processed using this method, and the processed results showed better accuracy and sensitivity to porosity than the unprocessed values.\",\"PeriodicalId\":265130,\"journal\":{\"name\":\"82nd EAGE Annual Conference & Exhibition\",\"volume\":\"617 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"82nd EAGE Annual Conference & Exhibition\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3997/2214-4609.202113190\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"82nd EAGE Annual Conference & Exhibition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3997/2214-4609.202113190","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A new determining porosity method based on four detectors and D-T neutron source
Summary The sensitivity of D-T neutron porosity logging to formation porosity change is lower than that of Am-Be neutron porosity logging.In order to improve the sensitivity of porosity measurement, based on a measurement system consisting of four detectors and D-T neutron source, The Monte Carlo simulation method was used to establish the numerical calculation model , the effects of density and hydrogen index on the thermal neutron count ratio and inelastic gamma count ratio are studied . A new method to correct the influence of density in porosity measurement by inelastic gamma count ratio is proposed. The data in the model well was processed using this method, and the processed results showed better accuracy and sensitivity to porosity than the unprocessed values.