A. L. F. Ferreira Filho, J. Cormane, D. C. Garcia, M. V. D. Costa, M. A. G. Oliveira, F. A. do Nascimento
{"title":"分析了由电压幅值和角度变化引起的复杂电压不平衡因素的行为","authors":"A. L. F. Ferreira Filho, J. Cormane, D. C. Garcia, M. V. D. Costa, M. A. G. Oliveira, F. A. do Nascimento","doi":"10.1109/ICHQP.2010.5625315","DOIUrl":null,"url":null,"abstract":"This paper presents the main aspects observed in analyzing Complex Voltage Unbalance Factor (CVUF) behavior resulting from the variation of voltage magnitudes and angles. The goal is to identify possible incoherencies regarding the use of the CVUF, and also to investigate whether this factor is more sensitive to variations in magnitude or angles under various voltage unbalance conditions. This study also evaluates the efficiency of the use of the CVUF angle and its association with positive component magnitudes. The results indicate that the CVUF should not be used as a single and sufficient parameter for the quantification of voltage unbalances, which highlights the need to develop a new indicator which may establish a more clear and simple association between this disturbance and its effects on electrical equipment.","PeriodicalId":180078,"journal":{"name":"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"Analysis of the complex voltage unbalance factor behavior resulting from the variation of voltage magnitudes and angles\",\"authors\":\"A. L. F. Ferreira Filho, J. Cormane, D. C. Garcia, M. V. D. Costa, M. A. G. Oliveira, F. A. do Nascimento\",\"doi\":\"10.1109/ICHQP.2010.5625315\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the main aspects observed in analyzing Complex Voltage Unbalance Factor (CVUF) behavior resulting from the variation of voltage magnitudes and angles. The goal is to identify possible incoherencies regarding the use of the CVUF, and also to investigate whether this factor is more sensitive to variations in magnitude or angles under various voltage unbalance conditions. This study also evaluates the efficiency of the use of the CVUF angle and its association with positive component magnitudes. The results indicate that the CVUF should not be used as a single and sufficient parameter for the quantification of voltage unbalances, which highlights the need to develop a new indicator which may establish a more clear and simple association between this disturbance and its effects on electrical equipment.\",\"PeriodicalId\":180078,\"journal\":{\"name\":\"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010\",\"volume\":\"25 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHQP.2010.5625315\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP.2010.5625315","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Analysis of the complex voltage unbalance factor behavior resulting from the variation of voltage magnitudes and angles
This paper presents the main aspects observed in analyzing Complex Voltage Unbalance Factor (CVUF) behavior resulting from the variation of voltage magnitudes and angles. The goal is to identify possible incoherencies regarding the use of the CVUF, and also to investigate whether this factor is more sensitive to variations in magnitude or angles under various voltage unbalance conditions. This study also evaluates the efficiency of the use of the CVUF angle and its association with positive component magnitudes. The results indicate that the CVUF should not be used as a single and sufficient parameter for the quantification of voltage unbalances, which highlights the need to develop a new indicator which may establish a more clear and simple association between this disturbance and its effects on electrical equipment.