电能表的误差

Андрій Вікторович Гнатов, Щасяна Валіковна Аргун, Олександр Андрійович Дзюбенко, Валентина Всеволодівна Тарасова, Сергій Михайлович Новічонок, Олена Василівна Войт
{"title":"电能表的误差","authors":"Андрій Вікторович Гнатов, Щасяна Валіковна Аргун, Олександр Андрійович Дзюбенко, Валентина Всеволодівна Тарасова, Сергій Михайлович Новічонок, Олена Василівна Войт","doi":"10.30977/veit.2018.13.0.66","DOIUrl":null,"url":null,"abstract":"Problem. The people’s demand for electricity has been growing year after year. This requires increasing the generation of electricity and reducing its losses on the way to a consumer. There is also a necessity to keep records of energy consumption. The main indicators characterizing the effectiveness of information and measuring technologies in the metering system are the accuracy of given measuring information and its reliability. The process of obtaining the information should be automated in order to provide the measuring information on time. In the electricity metering system, this is determined by the measuring principles and the quality of the metering system. Goal . Estimation of the errors of measuring transformers of different accuracy types, making recommendations on the choice of measuring transformers of different accuracy types and determining the ways to reduce any errors. Methodology . The methods of the theory of electromagnetic field and theoretical basis of electrical engineering have been used in the analysis and study of measuring transformer errors. The symbolic method of complex amplitudes and the methods of vector algebra have been applied to determine voltage errors and current errors. Results . The estimation of an error of measuring transformers of different accuracy types has been carried out. The recommendations on the choice of measuring transformers of different accuracy types have been made, and the main ways of reducing errors have been defined. Originality . The methods for estimating errors by current transformers and voltage transformers have been further developed. The methods of estimating errors in electric energy meters have been developed. The method of choosing current transformers has been improved taking into account various operational factors. Practical value. Any error of a current transformer depends on its loading capacity. The methods for reducing such errors have been defined. The factors that must be taken into account when applying the method of selecting current transformers aimed at reducing an error have been presented. The application of the given method of choosing current transformers will result in improvement of the measuring equipment value. This will increase the accuracy of the information being measured and allow reducing an error margin to a minimum value. Key words: current transformers; voltage transformers; electronic meters; meters of electrical energy; errors; measuring transformers.","PeriodicalId":153826,"journal":{"name":"Vehicle and electronics. Innovative technologies","volume":"46 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Errors of electronic meters of electric energy\",\"authors\":\"Андрій Вікторович Гнатов, Щасяна Валіковна Аргун, Олександр Андрійович Дзюбенко, Валентина Всеволодівна Тарасова, Сергій Михайлович Новічонок, Олена Василівна Войт\",\"doi\":\"10.30977/veit.2018.13.0.66\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Problem. The people’s demand for electricity has been growing year after year. This requires increasing the generation of electricity and reducing its losses on the way to a consumer. There is also a necessity to keep records of energy consumption. The main indicators characterizing the effectiveness of information and measuring technologies in the metering system are the accuracy of given measuring information and its reliability. The process of obtaining the information should be automated in order to provide the measuring information on time. In the electricity metering system, this is determined by the measuring principles and the quality of the metering system. Goal . Estimation of the errors of measuring transformers of different accuracy types, making recommendations on the choice of measuring transformers of different accuracy types and determining the ways to reduce any errors. Methodology . The methods of the theory of electromagnetic field and theoretical basis of electrical engineering have been used in the analysis and study of measuring transformer errors. The symbolic method of complex amplitudes and the methods of vector algebra have been applied to determine voltage errors and current errors. Results . The estimation of an error of measuring transformers of different accuracy types has been carried out. The recommendations on the choice of measuring transformers of different accuracy types have been made, and the main ways of reducing errors have been defined. Originality . The methods for estimating errors by current transformers and voltage transformers have been further developed. The methods of estimating errors in electric energy meters have been developed. The method of choosing current transformers has been improved taking into account various operational factors. Practical value. Any error of a current transformer depends on its loading capacity. The methods for reducing such errors have been defined. The factors that must be taken into account when applying the method of selecting current transformers aimed at reducing an error have been presented. The application of the given method of choosing current transformers will result in improvement of the measuring equipment value. This will increase the accuracy of the information being measured and allow reducing an error margin to a minimum value. Key words: current transformers; voltage transformers; electronic meters; meters of electrical energy; errors; measuring transformers.\",\"PeriodicalId\":153826,\"journal\":{\"name\":\"Vehicle and electronics. Innovative technologies\",\"volume\":\"46 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Vehicle and electronics. Innovative technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.30977/veit.2018.13.0.66\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vehicle and electronics. Innovative technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30977/veit.2018.13.0.66","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

问题。人民的用电需求逐年增长。这就需要增加发电量,减少电力在输送给消费者的过程中的损耗。也有必要保存能源消耗的记录。计量系统中信息测量技术有效性的主要指标是给定测量信息的准确性和可靠性。获取信息的过程应实现自动化,以便及时提供测量信息。在电能计量系统中,这是由计量原理和计量系统的质量决定的。的目标。对不同精度类型的测量变压器的误差进行估计,对不同精度类型的测量变压器的选择提出建议,并确定减小误差的方法。方法。利用电磁场理论的方法和电气工程的理论基础对变压器误差测量进行了分析和研究。用复幅的符号法和矢量代数的方法确定了电压误差和电流误差。结果。对不同精度类型的变压器进行了误差估计。对不同精度类型的测量变压器的选择提出了建议,并确定了减少误差的主要途径。创意。电流互感器和电压互感器的误差估计方法得到了进一步的发展。提出了电能表误差估计方法。在考虑各种运行因素的情况下,改进了电流互感器的选择方法。实用价值。电流互感器的任何误差都取决于它的负载能力。已经确定了减少这种误差的方法。提出了在选择电流互感器以减小误差时必须考虑的因素。应用所给出的电流互感器选择方法,可以提高测量设备的价值。这将增加被测量信息的准确性,并允许将误差范围减小到最小值。关键词:电流互感器;电压互感器;电子米;电能计量单位;错误;测量变压器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Errors of electronic meters of electric energy
Problem. The people’s demand for electricity has been growing year after year. This requires increasing the generation of electricity and reducing its losses on the way to a consumer. There is also a necessity to keep records of energy consumption. The main indicators characterizing the effectiveness of information and measuring technologies in the metering system are the accuracy of given measuring information and its reliability. The process of obtaining the information should be automated in order to provide the measuring information on time. In the electricity metering system, this is determined by the measuring principles and the quality of the metering system. Goal . Estimation of the errors of measuring transformers of different accuracy types, making recommendations on the choice of measuring transformers of different accuracy types and determining the ways to reduce any errors. Methodology . The methods of the theory of electromagnetic field and theoretical basis of electrical engineering have been used in the analysis and study of measuring transformer errors. The symbolic method of complex amplitudes and the methods of vector algebra have been applied to determine voltage errors and current errors. Results . The estimation of an error of measuring transformers of different accuracy types has been carried out. The recommendations on the choice of measuring transformers of different accuracy types have been made, and the main ways of reducing errors have been defined. Originality . The methods for estimating errors by current transformers and voltage transformers have been further developed. The methods of estimating errors in electric energy meters have been developed. The method of choosing current transformers has been improved taking into account various operational factors. Practical value. Any error of a current transformer depends on its loading capacity. The methods for reducing such errors have been defined. The factors that must be taken into account when applying the method of selecting current transformers aimed at reducing an error have been presented. The application of the given method of choosing current transformers will result in improvement of the measuring equipment value. This will increase the accuracy of the information being measured and allow reducing an error margin to a minimum value. Key words: current transformers; voltage transformers; electronic meters; meters of electrical energy; errors; measuring transformers.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信