500kv中性点小电抗接地自耦变压器的研究

Xu Yaotai, Zheng Meng, Gong Yueling, Chen Qiang
{"title":"500kv中性点小电抗接地自耦变压器的研究","authors":"Xu Yaotai, Zheng Meng, Gong Yueling, Chen Qiang","doi":"10.1109/ICAMMAET.2017.8186638","DOIUrl":null,"url":null,"abstract":"With the fast development of power system and the expansion of the scale, 500kV grid structure is greatly enhanced, and 500kV autotransformer runs in the neutral grounding mode, 220kV single-phase grounding fault current may exceed three-phase grounding fault current which affects the security and stability of power grid operation. In this paper, we mainly study the current level of single-phase grounding fault on the 220kV side of the 500kV autotransformer, which is changed from the direct grounding to the series reactor. The equivalent model of 500kV system is built as an example, explaining the principle of 500kV autotransformer with neutral point grounded through small reactance that can limit 220kV single-phase grounding fault current, calculating different resistance reactance restriction results on the single-phase grounding fault current of 220kV side.","PeriodicalId":425974,"journal":{"name":"2017 International Conference on Algorithms, Methodology, Models and Applications in Emerging Technologies (ICAMMAET)","volume":"726 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Study on 500 KV autotransformer with neutral point grounded through small reactance\",\"authors\":\"Xu Yaotai, Zheng Meng, Gong Yueling, Chen Qiang\",\"doi\":\"10.1109/ICAMMAET.2017.8186638\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"With the fast development of power system and the expansion of the scale, 500kV grid structure is greatly enhanced, and 500kV autotransformer runs in the neutral grounding mode, 220kV single-phase grounding fault current may exceed three-phase grounding fault current which affects the security and stability of power grid operation. In this paper, we mainly study the current level of single-phase grounding fault on the 220kV side of the 500kV autotransformer, which is changed from the direct grounding to the series reactor. The equivalent model of 500kV system is built as an example, explaining the principle of 500kV autotransformer with neutral point grounded through small reactance that can limit 220kV single-phase grounding fault current, calculating different resistance reactance restriction results on the single-phase grounding fault current of 220kV side.\",\"PeriodicalId\":425974,\"journal\":{\"name\":\"2017 International Conference on Algorithms, Methodology, Models and Applications in Emerging Technologies (ICAMMAET)\",\"volume\":\"726 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 International Conference on Algorithms, Methodology, Models and Applications in Emerging Technologies (ICAMMAET)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICAMMAET.2017.8186638\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 International Conference on Algorithms, Methodology, Models and Applications in Emerging Technologies (ICAMMAET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICAMMAET.2017.8186638","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

随着电力系统的快速发展和规模的扩大,500kV电网结构大大增强,500kV自适应变压器以中性点接地方式运行,220kV单相接地故障电流可能超过三相接地故障电流,影响电网运行的安全稳定。本文主要研究500kV自耦变压器220kV侧由直接接地改为串联电抗器后单相接地故障的电流水平。以500kV系统为例,建立等效模型,阐述了500kV中性点通过小电抗接地限制220kV单相接地故障电流的自耦变压器原理,计算了不同电阻电抗对220kV侧单相接地故障电流的限制结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Study on 500 KV autotransformer with neutral point grounded through small reactance
With the fast development of power system and the expansion of the scale, 500kV grid structure is greatly enhanced, and 500kV autotransformer runs in the neutral grounding mode, 220kV single-phase grounding fault current may exceed three-phase grounding fault current which affects the security and stability of power grid operation. In this paper, we mainly study the current level of single-phase grounding fault on the 220kV side of the 500kV autotransformer, which is changed from the direct grounding to the series reactor. The equivalent model of 500kV system is built as an example, explaining the principle of 500kV autotransformer with neutral point grounded through small reactance that can limit 220kV single-phase grounding fault current, calculating different resistance reactance restriction results on the single-phase grounding fault current of 220kV side.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信