恒流控制降压变换器中负载相互作用分析

M. Hankaniemi, T. Suntio, M. Sippola
{"title":"恒流控制降压变换器中负载相互作用分析","authors":"M. Hankaniemi, T. Suntio, M. Sippola","doi":"10.1109/INTLEC.2006.251638","DOIUrl":null,"url":null,"abstract":"The paper investigates the load interactions in constant-current-controlled buck converters. The nominal transfer functions and the load interaction formalism are derived from the voltage-output-converter model by applying duality. It is observed that the constant-current control makes the converter very sensitive to load interactions implying that a proper controller design is a necessity. The high crossover frequency in the nominal control-to-output transfer function may lead to performance degradation if the initial control design is done with resistive load, because the typical load for constant-current controlled converters is a low impedance storage-battery recovering the nominal feature. It is shown that electronic loads, typically used in prototype testing and verification, might have unexpected characteristics. This may lead to wrong deductions of the converter stability and performance","PeriodicalId":356699,"journal":{"name":"INTELEC 06 - Twenty-Eighth International Telecommunications Energy Conference","volume":"97 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Analysis of the Load Interactions in Constant-Current-Controlled Buck Converter\",\"authors\":\"M. Hankaniemi, T. Suntio, M. Sippola\",\"doi\":\"10.1109/INTLEC.2006.251638\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper investigates the load interactions in constant-current-controlled buck converters. The nominal transfer functions and the load interaction formalism are derived from the voltage-output-converter model by applying duality. It is observed that the constant-current control makes the converter very sensitive to load interactions implying that a proper controller design is a necessity. The high crossover frequency in the nominal control-to-output transfer function may lead to performance degradation if the initial control design is done with resistive load, because the typical load for constant-current controlled converters is a low impedance storage-battery recovering the nominal feature. It is shown that electronic loads, typically used in prototype testing and verification, might have unexpected characteristics. This may lead to wrong deductions of the converter stability and performance\",\"PeriodicalId\":356699,\"journal\":{\"name\":\"INTELEC 06 - Twenty-Eighth International Telecommunications Energy Conference\",\"volume\":\"97 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-12-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"INTELEC 06 - Twenty-Eighth International Telecommunications Energy Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/INTLEC.2006.251638\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"INTELEC 06 - Twenty-Eighth International Telecommunications Energy Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INTLEC.2006.251638","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本文研究了恒流控制降压变换器中的负载相互作用。利用对偶性导出了电压输出变换器模型的标称传递函数和负载相互作用形式。可以观察到,恒流控制使变换器对负载相互作用非常敏感,这意味着适当的控制器设计是必要的。如果初始控制设计采用阻性负载,则标称控制-输出传递函数中的高交叉频率可能导致性能下降,因为恒流控制变换器的典型负载是恢复标称特性的低阻抗蓄电池。结果表明,通常用于原型测试和验证的电子负载可能具有意想不到的特性。这可能导致对变换器稳定性和性能的错误推断
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analysis of the Load Interactions in Constant-Current-Controlled Buck Converter
The paper investigates the load interactions in constant-current-controlled buck converters. The nominal transfer functions and the load interaction formalism are derived from the voltage-output-converter model by applying duality. It is observed that the constant-current control makes the converter very sensitive to load interactions implying that a proper controller design is a necessity. The high crossover frequency in the nominal control-to-output transfer function may lead to performance degradation if the initial control design is done with resistive load, because the typical load for constant-current controlled converters is a low impedance storage-battery recovering the nominal feature. It is shown that electronic loads, typically used in prototype testing and verification, might have unexpected characteristics. This may lead to wrong deductions of the converter stability and performance
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信