{"title":"内置高电感线圈的片上磁传感器,用于生物磁学测量","authors":"HyunJune Lyu, Yun Sik Bae, V. Nair, J. Choi","doi":"10.1109/SAS.2014.6798921","DOIUrl":null,"url":null,"abstract":"Magnetic sensor chip for measuring biomagnetism is implemented in 0.18μm CMOS technology. The magnetic sensor chip consists of a small-sized high inductance coil sensor and an instrumentation amplifier (IA). The embedded high-inductance coil sensor contains suitable sensitivity and bandwidth for biomagnetic measurements, and is designed via electromagnetic field simulation. A low-gm operational transconductance amplifier is also implemented on the chip to reduce the transconductance value. The output signal sensitivity of the magnetic sensor chip is 3.25 fT/μV, and the output reference noise is 21.1 fT/ Hz. The instrumentation amplifier is designed to minimize the magnetic signal noise using current feedback and a band-pass filter with a bandwidth between 0.5 Hz and 5 kHz. The common-mode rejection ratio is measured at 117.5 dB by the Multi-Project Chip test. The proposed magnetic sensor chip is designed such that the input reference noise is maintained below 0.87 μV.","PeriodicalId":125872,"journal":{"name":"2014 IEEE Sensors Applications Symposium (SAS)","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"High inductance coil embedded on on-chip magnetic sensor for biomagnetism measurements\",\"authors\":\"HyunJune Lyu, Yun Sik Bae, V. Nair, J. Choi\",\"doi\":\"10.1109/SAS.2014.6798921\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Magnetic sensor chip for measuring biomagnetism is implemented in 0.18μm CMOS technology. The magnetic sensor chip consists of a small-sized high inductance coil sensor and an instrumentation amplifier (IA). The embedded high-inductance coil sensor contains suitable sensitivity and bandwidth for biomagnetic measurements, and is designed via electromagnetic field simulation. A low-gm operational transconductance amplifier is also implemented on the chip to reduce the transconductance value. The output signal sensitivity of the magnetic sensor chip is 3.25 fT/μV, and the output reference noise is 21.1 fT/ Hz. The instrumentation amplifier is designed to minimize the magnetic signal noise using current feedback and a band-pass filter with a bandwidth between 0.5 Hz and 5 kHz. The common-mode rejection ratio is measured at 117.5 dB by the Multi-Project Chip test. The proposed magnetic sensor chip is designed such that the input reference noise is maintained below 0.87 μV.\",\"PeriodicalId\":125872,\"journal\":{\"name\":\"2014 IEEE Sensors Applications Symposium (SAS)\",\"volume\":\"44 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-04-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE Sensors Applications Symposium (SAS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SAS.2014.6798921\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE Sensors Applications Symposium (SAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SAS.2014.6798921","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
High inductance coil embedded on on-chip magnetic sensor for biomagnetism measurements
Magnetic sensor chip for measuring biomagnetism is implemented in 0.18μm CMOS technology. The magnetic sensor chip consists of a small-sized high inductance coil sensor and an instrumentation amplifier (IA). The embedded high-inductance coil sensor contains suitable sensitivity and bandwidth for biomagnetic measurements, and is designed via electromagnetic field simulation. A low-gm operational transconductance amplifier is also implemented on the chip to reduce the transconductance value. The output signal sensitivity of the magnetic sensor chip is 3.25 fT/μV, and the output reference noise is 21.1 fT/ Hz. The instrumentation amplifier is designed to minimize the magnetic signal noise using current feedback and a band-pass filter with a bandwidth between 0.5 Hz and 5 kHz. The common-mode rejection ratio is measured at 117.5 dB by the Multi-Project Chip test. The proposed magnetic sensor chip is designed such that the input reference noise is maintained below 0.87 μV.