{"title":"基于光纤光栅温度计的组织反馈控制热治疗","authors":"S. Korganbayev, A. Orrico, Leonard M. Bianchi, M. Landrø, A. Wolf, A. Dostovalov, P. Saccomandi","doi":"10.1109/MeMeA52024.2021.9478749","DOIUrl":null,"url":null,"abstract":"Accurate treatment monitoring and control are essential factors to ensure safe and effective outcomes of thermal ablation therapies. In this work, we report a temperature feedback-controlled laser ablation system based on fiber Bragg grating (FBG) array measurements. A highly spatially resolved array of FBGs spaced at a distance of 0.01 mm was adopted to achieve accurate measurement of high-gradient temperature profiles during laser ablation in biological tissue. The temperature feedback-control based on FBG array measurements and on the subsequent laser current regulation was implemented to maintain stable peak temperature during ablation. The laser current was controlled based on the selection of threshold values, set for the maximum temperature in the laser-irradiated area, i.e., 43 °C, 48 °C, 55 °C, and 60 °C. The feedback-controlled system was validated comparing measured temperature maps during ablation and ablation results on the tissue surface. Finally, results suggest that our feedback system allows controlling the spatial extension of the ablated zone and preserving the maximum tissue temperature within useful ranges for a desired and optimal thermal ablation outcome.","PeriodicalId":429222,"journal":{"name":"2021 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Feedback-controlled thermal therapy of tissues based on fiber Bragg grating thermometers\",\"authors\":\"S. Korganbayev, A. Orrico, Leonard M. Bianchi, M. Landrø, A. Wolf, A. Dostovalov, P. Saccomandi\",\"doi\":\"10.1109/MeMeA52024.2021.9478749\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Accurate treatment monitoring and control are essential factors to ensure safe and effective outcomes of thermal ablation therapies. In this work, we report a temperature feedback-controlled laser ablation system based on fiber Bragg grating (FBG) array measurements. A highly spatially resolved array of FBGs spaced at a distance of 0.01 mm was adopted to achieve accurate measurement of high-gradient temperature profiles during laser ablation in biological tissue. The temperature feedback-control based on FBG array measurements and on the subsequent laser current regulation was implemented to maintain stable peak temperature during ablation. The laser current was controlled based on the selection of threshold values, set for the maximum temperature in the laser-irradiated area, i.e., 43 °C, 48 °C, 55 °C, and 60 °C. The feedback-controlled system was validated comparing measured temperature maps during ablation and ablation results on the tissue surface. Finally, results suggest that our feedback system allows controlling the spatial extension of the ablated zone and preserving the maximum tissue temperature within useful ranges for a desired and optimal thermal ablation outcome.\",\"PeriodicalId\":429222,\"journal\":{\"name\":\"2021 IEEE International Symposium on Medical Measurements and Applications (MeMeA)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-06-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE International Symposium on Medical Measurements and Applications (MeMeA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MeMeA52024.2021.9478749\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MeMeA52024.2021.9478749","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

准确的治疗监测和控制是保证热消融治疗安全有效的关键因素。在这项工作中,我们报道了一种基于光纤光栅阵列测量的温度反馈控制激光烧蚀系统。采用间距为0.01 mm的高空间分辨fbg阵列,实现了生物组织激光烧蚀过程中高梯度温度分布的精确测量。基于光纤光栅阵列测量和随后的激光电流调节实现温度反馈控制,以保持烧蚀过程中峰值温度的稳定。通过选择激光照射区域的最高温度阈值(43℃、48℃、55℃、60℃)来控制激光电流。通过对比消融过程中测量的温度图和组织表面的消融结果,对反馈控制系统进行了验证。最后,结果表明,我们的反馈系统可以控制消融区域的空间扩展,并将最高组织温度保持在有效范围内,以获得理想的最佳热消融结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Feedback-controlled thermal therapy of tissues based on fiber Bragg grating thermometers
Accurate treatment monitoring and control are essential factors to ensure safe and effective outcomes of thermal ablation therapies. In this work, we report a temperature feedback-controlled laser ablation system based on fiber Bragg grating (FBG) array measurements. A highly spatially resolved array of FBGs spaced at a distance of 0.01 mm was adopted to achieve accurate measurement of high-gradient temperature profiles during laser ablation in biological tissue. The temperature feedback-control based on FBG array measurements and on the subsequent laser current regulation was implemented to maintain stable peak temperature during ablation. The laser current was controlled based on the selection of threshold values, set for the maximum temperature in the laser-irradiated area, i.e., 43 °C, 48 °C, 55 °C, and 60 °C. The feedback-controlled system was validated comparing measured temperature maps during ablation and ablation results on the tissue surface. Finally, results suggest that our feedback system allows controlling the spatial extension of the ablated zone and preserving the maximum tissue temperature within useful ranges for a desired and optimal thermal ablation outcome.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信