小型变电站冲击接地阻抗现场测试研究

Si Wen-rong, Fu Chen-zhao, Chen Lu, Lu Qi-Yu, Bao Hai-long, Yuan Peng
{"title":"小型变电站冲击接地阻抗现场测试研究","authors":"Si Wen-rong, Fu Chen-zhao, Chen Lu, Lu Qi-Yu, Bao Hai-long, Yuan Peng","doi":"10.1109/icsgea.2018.00047","DOIUrl":null,"url":null,"abstract":"In this paper, application of a portable instrument to obtain impulse grounding impedance (IGI) characteristics for grounding grid of small substation is introduced. The test currents of 8/20 µs, 10/350 µs and 30/80 µs were chosen as the injection signal sources to the grounding grid respectively with simultaneous measurement of the response transient voltage waveshapes in time domain. The portable instrument and test object for experimental tests are simply described. Field tests were carried out to the grounding grid in a 35 kV substation for 3 consecutive times with different impulse currents, while the corresponding IGI calculated with processing of the impulse current and voltage waveshapes are also given. All of that provides a reference for basic research of lightning protection for the small substation and a better understanding of transient characteristics of grounding grid under the lightning stroke.","PeriodicalId":445324,"journal":{"name":"2018 International Conference on Smart Grid and Electrical Automation (ICSGEA)","volume":"229 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Research on Field Test of Impulse Grounding Impedance for Small Substation\",\"authors\":\"Si Wen-rong, Fu Chen-zhao, Chen Lu, Lu Qi-Yu, Bao Hai-long, Yuan Peng\",\"doi\":\"10.1109/icsgea.2018.00047\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, application of a portable instrument to obtain impulse grounding impedance (IGI) characteristics for grounding grid of small substation is introduced. The test currents of 8/20 µs, 10/350 µs and 30/80 µs were chosen as the injection signal sources to the grounding grid respectively with simultaneous measurement of the response transient voltage waveshapes in time domain. The portable instrument and test object for experimental tests are simply described. Field tests were carried out to the grounding grid in a 35 kV substation for 3 consecutive times with different impulse currents, while the corresponding IGI calculated with processing of the impulse current and voltage waveshapes are also given. All of that provides a reference for basic research of lightning protection for the small substation and a better understanding of transient characteristics of grounding grid under the lightning stroke.\",\"PeriodicalId\":445324,\"journal\":{\"name\":\"2018 International Conference on Smart Grid and Electrical Automation (ICSGEA)\",\"volume\":\"229 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 International Conference on Smart Grid and Electrical Automation (ICSGEA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/icsgea.2018.00047\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 International Conference on Smart Grid and Electrical Automation (ICSGEA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/icsgea.2018.00047","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文介绍了一种便携式仪器在小型变电站接地网冲击接地阻抗特性测量中的应用。分别选择试验电流为8/20 µs、10/350 µs和30/80 µs作为接地网的注入信号源,同时测量响应暂态电压的时域波形。简单介绍了实验测试的便携式仪器和测试对象。对35kv变电站接地网进行了连续3次不同冲击电流的现场试验,并给出了对冲击电流和电压波形进行处理计算的相应IGI。为小型变电站防雷的基础研究和更好地了解雷击作用下接地网的暂态特性提供了参考。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Research on Field Test of Impulse Grounding Impedance for Small Substation
In this paper, application of a portable instrument to obtain impulse grounding impedance (IGI) characteristics for grounding grid of small substation is introduced. The test currents of 8/20 µs, 10/350 µs and 30/80 µs were chosen as the injection signal sources to the grounding grid respectively with simultaneous measurement of the response transient voltage waveshapes in time domain. The portable instrument and test object for experimental tests are simply described. Field tests were carried out to the grounding grid in a 35 kV substation for 3 consecutive times with different impulse currents, while the corresponding IGI calculated with processing of the impulse current and voltage waveshapes are also given. All of that provides a reference for basic research of lightning protection for the small substation and a better understanding of transient characteristics of grounding grid under the lightning stroke.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信