弱电网条件下三相lcl型并网变换器锁相环小信号干扰补偿控制

Donghai Zhu, Shiying Zhou, X. Zou, Yong Kang, Kaifeng Zou
{"title":"弱电网条件下三相lcl型并网变换器锁相环小信号干扰补偿控制","authors":"Donghai Zhu, Shiying Zhou, X. Zou, Yong Kang, Kaifeng Zou","doi":"10.1109/ECCE.2018.8558372","DOIUrl":null,"url":null,"abstract":"For LCL-type grid-connected converter, the grid current control interacts with phase-locked loop (PLL) under weak grid, via point of common coupling (PCC) voltage. And PLL disturbance has negative effect on the grid current control. Thus, the grid current control renders undesired performance, even instability. To mitigate this problem, a simple small-signal disturbance compensation control method is proposed for three-phase LCL-type grid-connected converter. Under the proposed method, the negative small-signal disturbance effect of PLL dynamic on the grid current control can be reduced under weak grid, without changing the PLL parameters and structure. The current control performance and its robustness to the grid impedance changes are significantly improved. Moreover, the method is not influenced by the circuit parameters variation. Finally, the proposed method is validated by experiment.","PeriodicalId":415217,"journal":{"name":"2018 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":"{\"title\":\"Phase-Locked Loop Small-Signal Disturbance Compensation Control for Three-Phase LCL-Type Grid-Connected Converter under Weak Grid\",\"authors\":\"Donghai Zhu, Shiying Zhou, X. Zou, Yong Kang, Kaifeng Zou\",\"doi\":\"10.1109/ECCE.2018.8558372\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"For LCL-type grid-connected converter, the grid current control interacts with phase-locked loop (PLL) under weak grid, via point of common coupling (PCC) voltage. And PLL disturbance has negative effect on the grid current control. Thus, the grid current control renders undesired performance, even instability. To mitigate this problem, a simple small-signal disturbance compensation control method is proposed for three-phase LCL-type grid-connected converter. Under the proposed method, the negative small-signal disturbance effect of PLL dynamic on the grid current control can be reduced under weak grid, without changing the PLL parameters and structure. The current control performance and its robustness to the grid impedance changes are significantly improved. Moreover, the method is not influenced by the circuit parameters variation. Finally, the proposed method is validated by experiment.\",\"PeriodicalId\":415217,\"journal\":{\"name\":\"2018 IEEE Energy Conversion Congress and Exposition (ECCE)\",\"volume\":\"29 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE Energy Conversion Congress and Exposition (ECCE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ECCE.2018.8558372\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Energy Conversion Congress and Exposition (ECCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECCE.2018.8558372","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

摘要

对于lcl型并网变换器,电网电流控制通过共耦合点电压与弱电网下的锁相环相互作用。锁相环干扰对电网电流控制有不利影响。因此,电网电流控制呈现不理想的性能,甚至不稳定。针对这一问题,提出了一种简单的三相lcl型并网变换器的小信号干扰补偿控制方法。该方法可以在不改变锁相环参数和结构的前提下,降低弱电网条件下锁相环动态对电网电流控制的负小信号干扰效应。电流控制性能和对栅极阻抗变化的鲁棒性显著提高。此外,该方法不受电路参数变化的影响。最后,通过实验验证了该方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Phase-Locked Loop Small-Signal Disturbance Compensation Control for Three-Phase LCL-Type Grid-Connected Converter under Weak Grid
For LCL-type grid-connected converter, the grid current control interacts with phase-locked loop (PLL) under weak grid, via point of common coupling (PCC) voltage. And PLL disturbance has negative effect on the grid current control. Thus, the grid current control renders undesired performance, even instability. To mitigate this problem, a simple small-signal disturbance compensation control method is proposed for three-phase LCL-type grid-connected converter. Under the proposed method, the negative small-signal disturbance effect of PLL dynamic on the grid current control can be reduced under weak grid, without changing the PLL parameters and structure. The current control performance and its robustness to the grid impedance changes are significantly improved. Moreover, the method is not influenced by the circuit parameters variation. Finally, the proposed method is validated by experiment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信