{"title":"技术提示:改良胫骨远端锁定钢板固定肱骨远端关节外骨折","authors":"Rajul Gupta, Vaibhav Maheshwari, S. Gour, Narendra Kumar, Avtar Singh","doi":"10.17511/ijoso.2019.i03.02","DOIUrl":null,"url":null,"abstract":"Introduction- Treatment of extra-articular distal humerus fractures is often difficult using conventional plates. Plates having enough screws (three to four) in the distal fragment either impinge on the olecranon fossa, or gain purchase by placing screws in the lateral or medial column of the distal humerus avoiding the olecranon fossa. Objectives- This study was to ascertain the effectiveness of modified distal tibial locking plate for use in distal third shaft humerus fracture. Methods- By using a modified distal tibial locking plate, a six to eight locking head screws can be easily placed in the in the limited length of distal fragment proximal to the olecranon fossa. Fourteen cases treated in such manner were followed up for a minimum of 24 months. Results- Union was achieved in all cases with no loss of reduction or implant failure. No patient complained of hardware complication, functional limitation or infection. Conclusion- Modified distal locking plate can be safely used in the limited space above olecrenon fossa in distal thirds humerus shaft fractures","PeriodicalId":267909,"journal":{"name":"Surgical Update: International Journal of Surgery and Orthopedics","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Technical tip: fixation of extra-articular fractures of distal humerus with modified distal tibial locking plate\",\"authors\":\"Rajul Gupta, Vaibhav Maheshwari, S. Gour, Narendra Kumar, Avtar Singh\",\"doi\":\"10.17511/ijoso.2019.i03.02\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction- Treatment of extra-articular distal humerus fractures is often difficult using conventional plates. Plates having enough screws (three to four) in the distal fragment either impinge on the olecranon fossa, or gain purchase by placing screws in the lateral or medial column of the distal humerus avoiding the olecranon fossa. Objectives- This study was to ascertain the effectiveness of modified distal tibial locking plate for use in distal third shaft humerus fracture. Methods- By using a modified distal tibial locking plate, a six to eight locking head screws can be easily placed in the in the limited length of distal fragment proximal to the olecranon fossa. Fourteen cases treated in such manner were followed up for a minimum of 24 months. Results- Union was achieved in all cases with no loss of reduction or implant failure. No patient complained of hardware complication, functional limitation or infection. Conclusion- Modified distal locking plate can be safely used in the limited space above olecrenon fossa in distal thirds humerus shaft fractures\",\"PeriodicalId\":267909,\"journal\":{\"name\":\"Surgical Update: International Journal of Surgery and Orthopedics\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-08-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Surgical Update: International Journal of Surgery and Orthopedics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17511/ijoso.2019.i03.02\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgical Update: International Journal of Surgery and Orthopedics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17511/ijoso.2019.i03.02","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

引言-使用传统钢板治疗肱骨远端关节外骨折通常很困难。在远端碎片上有足够螺钉的钢板(三到四个),要么撞击鹰嘴窝,要么通过在肱骨远端外侧或内侧柱上放置螺钉来获得固定,避免鹰嘴窝。目的:本研究旨在确定改良胫骨远端锁定钢板用于肱骨远端第三骨干骨折的有效性。方法-使用改良的胫骨远端锁定钢板,可在鹰嘴窝近端有限长度的远端碎片内轻松放置6 - 8个锁定头螺钉。以这种方式治疗的14例患者至少随访24个月。结果:所有病例均成功愈合,无复位损失或种植体失败。没有患者抱怨硬件并发症,功能限制或感染。结论-改良远端锁定钢板可安全用于肱骨远端三分之一骨折尺骨鹰嘴窝上方有限空间
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Technical tip: fixation of extra-articular fractures of distal humerus with modified distal tibial locking plate
Introduction- Treatment of extra-articular distal humerus fractures is often difficult using conventional plates. Plates having enough screws (three to four) in the distal fragment either impinge on the olecranon fossa, or gain purchase by placing screws in the lateral or medial column of the distal humerus avoiding the olecranon fossa. Objectives- This study was to ascertain the effectiveness of modified distal tibial locking plate for use in distal third shaft humerus fracture. Methods- By using a modified distal tibial locking plate, a six to eight locking head screws can be easily placed in the in the limited length of distal fragment proximal to the olecranon fossa. Fourteen cases treated in such manner were followed up for a minimum of 24 months. Results- Union was achieved in all cases with no loss of reduction or implant failure. No patient complained of hardware complication, functional limitation or infection. Conclusion- Modified distal locking plate can be safely used in the limited space above olecrenon fossa in distal thirds humerus shaft fractures
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信