Fazila-tun-nesa Malik, -. Md Kalimuddin, N. Ahmed, M. Badiuzzaman
{"title":"第一代药物洗脱支架在支架放置10年后的极迟支架血栓形成:一例报告","authors":"Fazila-tun-nesa Malik, -. Md Kalimuddin, N. Ahmed, M. Badiuzzaman","doi":"10.3329/bhj.v36i2.56044","DOIUrl":null,"url":null,"abstract":"Stent thrombosis is one of the gravest complications of percutaneous coronary intervention which usually manifest as ST-segment elevation myocardial infarction or sudden death. There are a very few case reports in the literature regarding extremely late stent thrombosis in a drug-eluting stent. Here we report a case of extremely late stent thrombosis in a first generation drug-eluting stent in a 54 year old gentleman. To the best of our knowledge, this is the first case report with the longest duration (10 years) after sirolimus eluting first-generation DES in Bangladesh.\nBangladesh Heart Journal 2021; 36(2): 164-168","PeriodicalId":247590,"journal":{"name":"Bangladesh Heart Journal","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Extremely Late Stent Thrombosis in a First Generation Drug- Eluting Stent 10 Years After Stent Deployment: A Case Report\",\"authors\":\"Fazila-tun-nesa Malik, -. Md Kalimuddin, N. Ahmed, M. Badiuzzaman\",\"doi\":\"10.3329/bhj.v36i2.56044\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Stent thrombosis is one of the gravest complications of percutaneous coronary intervention which usually manifest as ST-segment elevation myocardial infarction or sudden death. There are a very few case reports in the literature regarding extremely late stent thrombosis in a drug-eluting stent. Here we report a case of extremely late stent thrombosis in a first generation drug-eluting stent in a 54 year old gentleman. To the best of our knowledge, this is the first case report with the longest duration (10 years) after sirolimus eluting first-generation DES in Bangladesh.\\nBangladesh Heart Journal 2021; 36(2): 164-168\",\"PeriodicalId\":247590,\"journal\":{\"name\":\"Bangladesh Heart Journal\",\"volume\":\"35 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bangladesh Heart Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3329/bhj.v36i2.56044\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bangladesh Heart Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3329/bhj.v36i2.56044","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Extremely Late Stent Thrombosis in a First Generation Drug- Eluting Stent 10 Years After Stent Deployment: A Case Report
Stent thrombosis is one of the gravest complications of percutaneous coronary intervention which usually manifest as ST-segment elevation myocardial infarction or sudden death. There are a very few case reports in the literature regarding extremely late stent thrombosis in a drug-eluting stent. Here we report a case of extremely late stent thrombosis in a first generation drug-eluting stent in a 54 year old gentleman. To the best of our knowledge, this is the first case report with the longest duration (10 years) after sirolimus eluting first-generation DES in Bangladesh.
Bangladesh Heart Journal 2021; 36(2): 164-168